European journal of pediatrics
-
Multicenter Study
Pulse oximeter saturation target limits for preterm infants: a survey among European neonatal intensive care units.
The optimum range of pulse oximeter oxygen saturation (SpO2) for preterm infants remains controversial. Between November 2015 and February 2016, we conducted a web-based survey aimed to investigate the current and former practices on SpO2 targets in European neonatal intensive care units (NICUs). We obtained valid responses from 193 NICUs, treating 8590 newborns ≤28 weeks per year, across 27 countries. ⋯ The most frequently reported former limits were 88-92% (18%), 85-95% (9%), 88-93 (7%), and 85-92% (6%). The NICUs that increased their SpO2 ranges expected to obtain a reduction in mortality. A 54% of the NICUs found the scientific evidence supporting their SpO2 targeting policy strong or very strong.