Spine
-
Multicenter Study Comparative Study Clinical Trial
Comparison of anterior and posterior instrumentation for correction of adolescent thoracic idiopathic scoliosis.
This was a prospective study of two cohort groups of patients (one group receiving anterior instrumentation and the other posterior instrumentation) receiving treatment for thoracic idiopathic scoliosis. ⋯ 1) Coronal correction and balance were equal in both the anterior and posterior groups, even though the anterior group had the majority of curves (97%) fused short or to L1, whereas only 18% were fused short or to L1 in the posterior group. 2) In the anterior group there was a better correction of sagittal profile in those with a preoperative hypokyphosis less than 20 degrees. However, hyperkyphosis (with a mean of 54 degrees) occurred in 40% of those in the anterior group with a preoperative kyphosis of more than 20 degrees. 3) An average of 2.5 lumbar levels can be saved with anterior fusion and instrumentation according to the criteria used for choosing posterior fusion levels in this study. 4) Using the 3.2-mm flexible rod in this study, loss of correction, pseudarthrosis, and rod breakage were unacceptably highe
-
Repeated measures design for intra- and interrater reliability. ⋯ The poor reliability of the American Medical Association Guides' spinal range of motion model can result in marked variation in the percentage of whole-body impairment. These findings have implications for compensation bodies in Australia and other countries that use the American Medical Association Guides' procedure to estimate impairment in chronic low back pain patients.
-
The primary biomechanical stability of anterior internal fixation of the cervical spine obtained with a new monocortical expansion screw in vitro was evaluated. ⋯ In anterior instrumentation of the cervical spine using a H-plate, the new monocortical expansion screw provides the same biomechanical stability as the bicortical 3.5-mm AO screw and a significantly better biomechanical stability than the cervical spine locking plate. Therefore, the expansion screw may be an alternative to the bicortical fixation and does not involve the risk of penetration of the posterior vertebral body cortex.
-
A controlled study with a 6-month follow-up period. ⋯ The results support the hypothesis that chronic low back trouble (i.e., pain, psychological distress, and general disability) hampers the functioning of short-term memory, which results in decreased speed of information processing among patients with chronic low back trouble.
-
A case is reported in which late displacement of a "hangman's fracture" was managed by transoral C2-C3 fusion by using bicortical iliac crest graft and a titanium cervical locking plate. ⋯ Undisplaced fractures of the axis are not always stable. The transoral route allows good access for stabilization of displaced hangman's fractures. In special circumstances, a locking plate may prove useful in securing the bone graft. The cervical spine locking plate can be inserted transorally with no complications and by using standard instrumentation.