Der Internist
-
Pathological coagulation parameters may reflect life-threatening hemorrhagic or thromboembolic diseases but may also be a laboratory result without any clinical significance, result from in vitro phenomena or preanalytical errors. This article gives an overview of potential pitfalls in coagulation diagnostics, lists the differential diagnoses of pathological coagulation parameters and describes further steps in the diagnostic approach to clarify pathological results. The focus lies on coagulation parameters that are frequently determined in routine clinical investigations, e.g. platelet count, prothrombin time, activated partial thromboplastin time (aPTT) and fibrinogen. ⋯ The clinical utility of D-dimer assays is limited by their poor specificity. Elevated D-dimer concentrations can be found in various diseases and also under normal physiological circumstances (e.g. in the elderly). Thus, the most useful clinical application of D-dimer is evidence of normal values to essentially rule out venous thromboembolism.