Journal of biomechanical engineering
-
The viscoelastic behavior of tendons has been extensively studied in vitro. A noninvasive method by which to acquire mechanical data would be highly beneficial, as it could lead to the collection of viscoelastic data in vivo. Our lab has previously presented acoustoelasticity as an alternative ultrasound-based method of measuring tendon stress and strain by reporting a relationship between ultrasonic echo intensity (B mode ultrasound image brightness) and mechanical behavior of tendon under pseudoelastic in vitro conditions [Duenwald, S., Kobayashi, H., Frisch, K., Lakes, R., and Vanderby Jr, R., 2011, "Ultrasound Echo is Related to Stress and Strain in Tendon," J. ⋯ We also report that the patterns of the echo intensity changes do not directly mimic the patterns of viscoelastic load changes, but the intensity changed in a repeatable (and therefore predictable) fashion. Although mechanisms need further elucidation, viscoelastic behavior can be anticipated from echo intensity changes. This phenomenon could potentially lead to a more extensive characterization of in vivo tissue behavior.
-
Unilateral below-knee amputees develop abnormal gait characteristics that include bilateral asymmetries and an elevated metabolic cost relative to non-amputees. In addition, long-term prosthesis use has been linked to an increased prevalence of joint pain and osteoarthritis in the intact leg knee. To improve amputee mobility, prosthetic feet that utilize elastic energy storage and return (ESAR) have been designed, which perform important biomechanical functions such as providing body support and forward propulsion. ⋯ The analyses showed that altering a nominal prosthetic foot stiffness distribution by stiffening the toe and mid-foot while making the ankle and heel less stiff improved ESAR foot performance by offloading the intact knee during early to mid-stance of the intact leg and reducing metabolic cost. The optimal design also provided moderate braking and body support during the first half of residual leg stance, while increasing the prosthesis contributions to forward propulsion and body support during the second half of residual leg stance. Future work will be directed at experimentally validating these results, which have important implications for future designs of prosthetic feet that could significantly improve amputee care.
-
Radio frequency energy (RFE) thermal chondroplasty has been a widely-utilized method of cartilage debridement in the past. Little is known regarding its effect on tissue mechanics. This study investigated the acute biomechanical effects of bipolar RFE treatment on human chondromalacic cartilage. ⋯ Tissue permeability decreased in Grade II and III specimens from 2.04 ∗10(-15) m(4)/Ns to 0.91 ∗10(-15) m(4)/Ns (P < 0.001 and P = 0.009, respectively). RFE treatment decreased thickness, time constant, fibril modulus, permeability, but increased peak force, equilibrium force, and matrix modulus. While resistance to shear and tension could be compromised due to removal of the superficial layer and decreased fibril modulus, RFE treatment increases matrix modulus and decreases tissue permeability which may restore the load- bearing capacity of the cartilage.
-
Modeling of the cerebrospinal fluid (CSF) system in the spine is strongly motivated by the need to understand the origins of pathological conditions such as the emergence and growth of fluid-filled cysts in the spinal cord. In this study, a one-dimensional (1D) approximation for the flow in elastic conduits was used to formulate a model of the spinal CSF compartment. The modeling was based around a coaxial geometry in which the inner elastic cylinder represented the spinal cord, middle elastic tube represented the dura, and the outermost tube represented the vertebral column. ⋯ The results obtained from the 1D model and its FE counterpart were found to be in good general agreement even when sharp spatial gradients of the spinal cord stiffness were included; both models predicted large radial displacements of the cord at the location of an initial cyst. This study suggests that 1D modeling, which is computationally inexpensive and amenable to coupling with the models of the cranial CSF system, should be a useful approach for the analysis of some aspects of the CSF dynamics in the spine. The simulation of the CSF pulse excited by a pressure disturbance in the epidural space, points to the possibility that regions of the spinal cord with abnormally low stiffness may be prone to experiencing large strains due to coughing and sneezing.
-
While many congenital heart defects can be treated without significant long term sequelae, some achieve successful palliation as their definitive endpoints. The single-ventricle defect is one such defect and leaves the child with only one operational ventricle, requiring the systemic and the pulmonary circulations to be placed in series through several operations performed during early childhood. Numerical simulations may be used to investigate these hemodynamic conditions and their relation to post-operative sequelae; however, they rely heavily on boundary condition prescription. ⋯ To increase the precision of such indicators, mean flow split between right and left lungs needs to be measured with more accuracy with higher priority than refining the model of how the flow is distributed on average among the smaller branches. Although ± 10% flow split imprecision seemed reasonable in terms of patient comparison, this study suggests that the common practice of imposing a right pulmonary artery/left pulmonary artery flow split of 55%/45% when performing patient specific simulations should be avoided. This study constitutes a first step towards understanding the hemodynamic differences between pre- and post Fontan surgery, predicting these differences, and evaluating surgical outcomes based on preoperative data.