The Journal of hospital infection
-
The Dutch Working Party on Infection Prevention (WIP) aimed to determine whether certain humidification policies are better than others in terms of prevention of ventilator-associated pneumonia (VAP) in mechanically ventilated intensive care unit (ICU) patients. Publications were retrieved by a systematic search of Medline and the Cochrane Library up to February 2006. All (quasi-) randomized trials and systematic reviews/meta-analyses comparing humidification methods in ventilated ICU patients were selected. ⋯ WIP do not recommend either passive or active humidifiers to prevent VAP, nor the type of passive humidifiers to be used. Regarding active humidification, WIP recommends using heated wire circuits. This is due to the theoretical consideration that less condensate reduces colonization and subsequent risk of spread throughout an ICU when condensate is removed.