Klinische Pädiatrie
-
Klinische Pädiatrie · Jul 2014
ReviewAutomated adjustments of inspired fraction of oxygen to avoid hypoxemia and hyperoxemia in neonates - a systematic review on clinical studies.
Supplemental oxygen is commonly provided during transition of neonates immediately after birth. Whereas an initial FiO2 of 0.21 is now recommended to stabilize full-term infants in the delivery room, the best FiO2 to start resuscitation of the very low birth weight infant (VLBWI) immediately after delivery is currently not known. Recent recommendations include the use of pulse oximetry to titrate the use of supplemental oxygen. ⋯ These studies could demonstrate short-term benefits such as more stable arterial oxygen saturation. Recent clinical trials have shown that oxygen targeting may significantly affect mortality and morbidity. Therefore, randomized controlled trials are needed to study the effects of automated FiO2-adjustment on long-term outcomes to prove possible benefits on survival, the rate of retino-pathy of prematurity and on neuro-development-al outcome.