Magnetic resonance imaging
-
We present three-dimensional adiabatic inversion recovery prepared ultrashort echo time Cones (3D IR-UTE-Cones) imaging of cortical bone in the hip of healthy volunteers using a clinical 3T scanner. ⋯ The 3D IR-UTE-Cones sequence allows in vivo volumetric imaging and quantitative T2⁎ measurement of cortical bone in the hip using a clinical 3T scanner.
-
To implement and evaluate interleaved blip-up, blip-down, non-segmented 3D echo planar imaging (EPI) with pseudo-continuous arterial spin labeling (pCASL) and post-processing for reduced susceptibility artifact cerebral blood flow (CBF) maps. ⋯ Pseudo-continuous arterial spin labeling with non-segmented 3D EPI acquisition using alternating blip-reversed k-space traversal and distortion correction provided significantly better matching GM CBF maps. In addition, employing alternating blip-reversed acquisitions during pCASL acquisition resulted in statistically significant improvement over corrected blip-up and blip-down CBF maps.
-
A gravitational valve (GV) may be used to treat hydrocephalus, offering possible advantages that include avoidance of over drainage and long-term complications. Because a GV is made from metal, there are potential safety and other problems related to the use of MRI. The objective of this investigation was to evaluate MRI-related issues (i.e., magnetic field interactions, heating, and artifacts) for a newly developed, metallic GV. ⋯ The findings demonstrated that MRI can be safely used in patients with this GV and, thus, this metallic implant is deemed acceptable or "MR Conditional" (i.e., using current labeling terminology), according to the conditions used in this study.
-
To develop a technique for three dimensional (3D) high resolution joint imaging of intracranial and extracranial arterial walls with improved cerebrospinal fluid (CSF) suppression and good blood suppression based on T1 weighted sampling perfection with application optimized contrast using different angle evolutions (T1w-SPACE) and to compare this technique (hereafter, iSPACE) with alternating with nutation for tailored excitation (DANTE) prepared SPACE sequence (DANTE-SPACE) for their CSF suppression performance around the mid cerebral arteries (MCA) and blood suppression at carotid arteries. ⋯ Simultaneous extracranial and intracranial arterial wall imaging using iSPACE improved CSF suppression significantly at the M2 segment of MCA while blood suppression was comparable to DANTE-SPACE. The technique achieved 3D images with 0.6mm isotropic spatial resolution and took 7.5min using a custom made coil set. Using this technique, intracranial plaque visualization was improved with no observable image SNR degradation.