The American journal of emergency medicine
-
This study assessed long-term emergency care utilization after weight loss surgery. ⋯ Persistent and resource-intensive emergency care utilization after weight loss surgery underscores the need of long-term patient support.
-
Feedback devices are used to improve the quality of chest compression (CC). However, reports have noted that accelerometers substantially overestimate depth when cardiopulmonary resuscitation (CPR) is performed on a soft surface. Here, we determined whether a flexible pressure sensor could correctly evaluate the depth CC performed on a mannequin placed on a mattress. ⋯ The Shinnosukekun(™) could correctly measure the depth of CC on a mattress. According to our present results, the flexible pressure sensor could be a useful feedback system for CC performed on a soft surface.
-
Case Reports
Simple pneumopericardium due to blunt trauma progressing to tension pneumopericardium during transportation.
Patients with simple pneumopericardium due to blunt thoracic trauma occasionally progressed to tension pneumopericardium, although pneumopericardium is believed to be benign in general. A 65-year-old man had both arms caught in a grinding machine and his face struck hard at work. He was diagnosed with bilateral degloving injuries of both arms and mediastinal emphysema on computed tomography. ⋯ The patient returned to the local hospital as cardiopulmonary resuscitation continued, repeat computed tomography was performed, which showed a substantial pneumopericardium and exacerbation of mediastinal and subcutaneous emphysema. After then, cardiopulmonary resuscitation was discontinued because there was no response. For the patient to be rescued in this situation, thoracotomy is required, although it should be reserved for patients with evidence of hemodynamic compromise attributable to cardiac tamponade.
-
Letter Randomized Controlled Trial Comparative Study
A randomized crossover trial comparing the C-MAC and Macintosh laryngoscopes for face-to-face intubation in a manikin.
-
Vortex tubes are simple mechanical devices to produce cold air from a stream of compressed air without any moving parts. The primary focus of the current study is to investigate the feasibility and efficiency of nasopharyngeal brain cooling method using a vortex tube. Experiments were conducted on 5 juvenile pigs. ⋯ Similarly, by using medical air cylinders at fill-pressure of 2265 PSI and down regulate the inlet pressure to the vortex tube to 50 PSI, brain temperature could be reduced more rapidly by blowing -22°C ± 2°C air at a flow rate of 50 L/min; brain-body temperature gradient of -8°C was obtained about 30 minutes. Furthermore, we examined scuba cylinders as a portable source of compressed gas supply to the vortex tube. Likewise, by setting up the vortex tube to have an inlet pressure of 25 PSI and 50 L/min and -3°C at the cold air outlet, brain temperature decreased 4.5°C within 10-20 min.