Resuscitation
-
Comparative Study Clinical Trial
A new external upper airway opening device combined with a cervical collar.
Airway problems are the main cause of mortality in otherwise survivable trauma injuries. We developed a novel external airway protector in combination with a cervical collar. The new device simultaneously opens the airway and protects the cervical spine. ⋯ The new external non-invasive airway device (Lubo Collar) is safe and effective in opening and maintaining an open airway in an unconscious anaesthetised patient with a blocked airway. These preliminary results may encourage assessment in the field.
-
This study aims to determine the failure rate of transplanted kidney grafts in recipients of organs from non-heart beating donors (NHBDs) who have had mechanical chest compressions to maintain a circulation before organ retrieval. ⋯ We have described our experience and protocol for non-heart beating donation using victims of out-of-hospital cardiac arrest in whom cardiopulmonary resuscitation has been unsuccessful as donors. Primary kidney graft failure rates in organs from non-heart beating donors is similar when manual or mechanical chest compression devices are used during cardiopulmonary resuscitation.
-
In order to improve the quality of our Emergency Medical Services (EMS), to raise bystander cardiopulmonary resuscitation rates and thereby meet what is becoming a universal standard in terms of quality of emergency services, we decided to implement systematic dispatcher-assisted or telephone-CPR (T-CPR) in our medical dispatch center, a non-Advanced Medical Priority Dispatch System. The aim of this article is to describe the implementation process, costs and results following the introduction of this new "quality" procedure. ⋯ This study demonstrates it is possible, using a brief campaign of sensitization but without any specific training, to implement systematic dispatcher-assisted cardiopulmonary resuscitation in a non-Advanced Medical Priority Dispatch System such as our EMS that had no prior experience with systematic T-CPR. The results in terms of T-CPR delivery rate and false positive are similar to those found in previous studies. We found our results satisfying the given short time frame of this study. Our results demonstrate that it is possible to improve the quality of emergency services at moderate or even no additional costs and this should be of interest to all EMS that do not presently benefit from using T-CPR procedures. EMS that currently do not offer T-CPR should consider implementing this technique as soon as possible, and we expect our experience may provide answers to those planning to incorporate T-CPR in their daily practice.
-
Determine the effect of residual leaning force on intrathoracic pressure (ITP) in healthy children receiving mechanical ventilation. We hypothesized that application of significant residual leaning force (2.5kg or 20% of subject body weight) would be associated with a clinically important change in ITP. ⋯ In healthy anesthetized children, changes in ETP were detectable at residual leaning forces as low as 10% of subject body weight. Residual leaning force of 2.5kg was associated with increases in ETP >or=2.0cmH(2)O.
-
Telephone-cardiopulmonary resuscitation (CPR) advice aims to increase the quality and quantity of bystander CPR, one of the few interventions shown to improve outcome in cardiac arrest. We evaluated a current paediatric telephone protocol (AMPDS v11.1) to assess the effectiveness of verbal CPR instructions in paediatric cardiac arrest. ⋯ Although current telephone-CPR instructions improve the numbers of children in whom bystander CPR is attempted, effectiveness is likely to be limited by the significant delays in actually delivering basic life support.