Journal of sports sciences
-
Low-pass filters are ideal when filtering human movements, however the effectiveness of such filters relies on the correct selection of the cut-off frequency. The aim of this study was to determine the most appropriate filter cut-off for acceleration- and force-time data when measuring peak resultant acceleration (PRA) and ground reaction force (PRGRF) during gymnastics landings. Sixteen gymnasts executed backward handsprings and backward somersault landings onto a matted force plate while wearing four inertial measurement units (IMUs). ⋯ Results indicated that a minimum 85 Hz cut-off is optimal. High cut-off frequencies (>80 Hz) showed good linear relationships and had minimal mean bias compared with raw values, indicating that either filtered (above ~85 Hz) or raw signals can be used. It is suggested that for applied sports settings no filtering is needed, however a minimum cut-off of 85 Hz should be implemented for research purposes.