Journal of vascular surgery
-
Multicenter Study Comparative Study
Prospective evaluation of electroencephalography, carotid artery stump pressure, and neurologic changes during 314 consecutive carotid endarterectomies performed in awake patients.
This study attempted to correlate neurologic changes in awake patients undergoing carotid endarterectomy (CEA) under cervical block anesthesia (CBA) with electroencephalography (EEG) and measurement of carotid artery stump pressure (SP). ⋯ Ten percent of patients required a shunt placement during CEA under CBA. Shunt placement was necessary in 56.8% of patients with SP less than 40 mm Hg. EEG identified cerebral ischemia in only 59.4% of patients needing shunt placement, with a false-positive rate of 1.0% and a false-negative rate of 40.6%. Both SP and EEG as a guide to shunt placement have poor sensitivity. Intraoperative monitoring of the awake patients under regional anesthesia (CBA) is the most sensitive and specific method to identify patients requiring shunt placement.