Journal of vascular surgery
-
Randomized Controlled Trial Comparative Study
A prospective randomized study of stent graft placement after balloon angioplasty versus balloon angioplasty alone for the treatment of hemodialysis patients with prosthetic graft outflow stenosis.
Hemodialysis graft outflow stenosis is a significant complication occurring in hemodialysis patients with prosthetic grafts for vascular access. Balloon angioplasty remains the first-line endovascular treatment of this complication, although covered stent graft implantation after balloon angioplasty also appears to be an effective and promising treatment. The aim of this study was to evaluate the efficacy and durability of stent graft placement after balloon angioplasty in comparison to balloon angioplasty alone for the treatment of graft outflow stenosis in hemodialysis patients. ⋯ The use of stent grafts in hemodialysis patients with graft outflow stenosis yielded superior results compared with the results seen in hemodialysis patients treated with balloon angioplasty alone. Patients treated with stent grafts after balloon angioplasty had a lower restenosis rate and a longer duration of postintervention primary patency. The placement of a stent graft after balloon angioplasty appears to be an optimal therapeutic approach for the treatment of hemodialysis patients with graft outflow stenosis.