European journal of anaesthesiology
-
Multicenter Study Clinical Trial Controlled Clinical Trial
Multicentre evaluation of in vitro contracture testing with bolus administration of 4-chloro-m-cresol for diagnosis of malignant hyperthermia susceptibility.
The in vitro contracture test with halothane and caffeine is the gold standard for the diagnosis of susceptibility to malignant hyperthermia (MH). However, the sensitivity of the in vitro contracture test is between 97 and 99% and its specificity is 78-94% with the consequence that false-negative as well as false-positive test results are possible. 4-Chloro-m-cresol is potentially a more specific test drug for the in vitro contracture test than halothane or caffeine. This multicentre study was designed to investigate whether an in vitro contracture test with bolus administration of 4-chloro-m-cresol can improve the accuracy of the diagnosis of susceptibility to MH. ⋯ The in vitro contracture test with halothane and caffeine is well standardized in the European and North American test protocols. However, this conventional test method is associated with the risk of false test results. Therefore, an improvement in the diagnosis of MH is needed. Regarding the results from this multicentre study, the use of 4-chloro-m-cresol could increase the reliability of in vitro contracture testing.