European journal of anaesthesiology
-
Randomized Controlled Trial
Effectiveness of head-mounted ultrasound display for radial arterial catheterisation in paediatric patients by anaesthesiology trainees: A randomised clinical trial.
The effectiveness of head mounted real-time ultrasound displays (hereafter referred to as 'smart glasses') in improving hand-eye coordination in less experienced individuals, such as trainees in anaesthesia, is unclear. ⋯ Smart glasses-assisted ultrasound guided radial artery catheterisation improved the first attempt success rate among anaesthesiology trainees, reducing the number of attempts and overall complication rates in small paediatric patients. Smart glasses were more effective for anaesthesia residents (CA 2-4 years) but were not effective for paediatric anaesthesiology fellows (CA 5 years).
-
Randomized Controlled Trial
Effect of different lung recruitment strategies and airway device on oscillatory mechanics in children under general anaesthesia.
Atelectasis has been reported in 68 to 100% of children undergoing general anaesthesia, a phenomenon that persists into the recovery period. Children receiving recruitment manoeuvres have less atelectasis and fewer episodes of oxygen desaturation during emergence. The optimal type of recruitment manoeuvre is unclear and may be influenced by the airway device chosen. ⋯ Although there was no significant difference between airway devices, this study demonstrated more effective recruitment via repeated inflations than sustained inflation in anaesthetised children.