Pilot study evaluating a non-titrating, weight-based anticoagulation scheme for patients on veno-venous extracorporeal membrane oxygenation.
There is no universally accepted algorithm for anticoagulation in patients on veno-venous extracorporeal membrane oxygenation. The purpose of this pilot study was to compare a non-titrating weight-based heparin infusion to that of a standard titration algorithm. ⋯ In this pilot study, a non-titrating, weight-based heparin infusion appears safe and as effective in preventing veno-venous extracorporeal membrane oxygenation circuit thrombotic complications as compared to a titration algorithm. Larger studies are needed to confirm these preliminary findings.