Renal failure
-
Randomized Controlled Trial Comparative Study
A comparison of articaine and fentanyl-supplemented articaine for hemodialysis fistula creation under ultrasound-guided axillary block.
The aim of this prospective randomized, double-blinded study was to evaluate the effect of fentanyl addition to articaine on the duration of sensory as well as motor blocks, and the duration of analgesia during hemodialysis fistula creation under ultrasound-guided axillary block. Fifty patients were randomly allocated to two groups, an articaine group (A), receiving 40 mL of articaine HCI (20 mg/mL) with 2 mL of isotonic sodium chloride solution, and an articaine-fentanyl group (AF), receiving 40 mL of articaine HCI (20 mg/mL) with 2 mL (100 µg) of fentanyl. The onset as well as the duration of sensory and motor blocks, the time necessary for first analgesic administration, the hemodynamic parameters, and the side effects were recorded. ⋯ The addition of fentanyl did not improve the onset of sensory and motor block times. Hemodynamic parameters were similar in the two groups. In conclusion, the addition of fentanyl to articaine in axillary block prolongs the duration of sensory and motor blocks, as well as the time of first analgesic requirement.
-
Randomized Controlled Trial Comparative Study
The comparative safety of various intravenous iron preparations in chronic kidney disease patients.
The relative safety of parenteral iron preparations is a controversial issue in the management of anemia in chronic kidney disease (CKD), as direct head-to-head comparative trials are lacking. In this study, patients of CKD were randomized to receive intravenous low molecular weight iron dextran (ID), sodium ferrigluconate complex (SFGC), and iron sucrose (IS) at doses and infusion rates recommended by the product manufacturer. One time test dose was used only for ID and SFGC. ⋯ No significant difference was seen between the three groups in terms of non-serious ADEs. Drug discontinuation occurred significantly more often with ID. One patient who developed anaphylactoid reaction with SFGC and ID tolerated iron sucrose well.
-
Randomized Controlled Trial Comparative Study
Effects of normal saline vs. lactated ringer's during renal transplantation.
We hypothesized that normal saline (NS) may have more deleterious effects compared with lactated ringer (LR) in kidney transplant recipients because of the higher risk of acidosis and higher levels of serum potassium. Thus, the aim of this study was to determine the safety of LR if used during a renal transplant. ⋯ Compared with NS, LR infusion may lead to a lower serum potassium level and a lower risk of acidosis, while there is major concern of the hypercoagulable state in these patients.
-
Randomized Controlled Trial Comparative Study
Predictive factors and therapeutic approach of renovascular disease: four years' follow-up.
There is no consensus about the renal function outcome after revascularization with stenting in atherosclerotic renovascular disease. In the present study, the outcome in BP control and renal function in patients with renovascular disease treated with percutaneous angioplasty and stent placement is compared with the outcome in patients with renovascular disease treated with medical treatment only. Additionally, the impact of oxidative stress and eosinophil count in peripheral blood as predictors of renal function deterioration in renovascular disease irrespective of treatment is investigated. ⋯ Revascularization was not superior to medical treatment in renal survival but had a greater positive impact on blood pressure control. Eosinophil count and oxidative stress were the stronger predictive factors for serum creatinine increase.
-
Randomized Controlled Trial Comparative Study
A prospective randomized study to compare ultrasound-guided with nonultrasound-guided double lumen internal jugular catheter insertion as a temporary hemodialysis access.
Internal jugular venous catheters (IJVC) for hemodialysis are a commonly employed temporary vascular access for hemodialysis. Most hospitals still follow the use of blind technique, which uses anatomical landmarks. Even in the most experienced hands this procedure has a variable success rate. Ultrasound guidance can decrease the incidence of periprocedural complications and improve the success rate. In this randomized study we compared the procedure success rate and periprocedural complications in patients undergoing ultrasound guided vs. nonultrasound guided IJVC insertion for a temporary hemodialysis access. ⋯ Ultrasound guided procedure for internal jugular vein catheter insertion using an ordinary ultrasound machine was significantly safer and more successful as compared to the blind technique.