Canadian journal of anaesthesia = Journal canadien d'anesthésie
-
Randomized Controlled Trial
The impact of a barrier enclosure on time to tracheal intubation: a randomized controlled trial.
Novel devices such as the barrier enclosure were developed in hopes of improving provider safety by limiting SARS-CoV-2 transmission during tracheal intubation. Nevertheless, concerns arose regarding a lack of rigorous efficacy and safety data for these devices. We conducted a randomized controlled trial to evaluate the impact of the barrier enclosure on time to tracheal intubation. ⋯ In healthy surgical patients with normal airway predictors, the use of a barrier enclosure during tracheal intubation did not significantly prolong time to intubation or decrease first-pass intubation success. Nevertheless, there was an increase in difficulty of intubation perceived by the anesthesiologists with use of a barrier enclosure.
-
Observational Study
Seven years on from the Canadian Airway Focus Group Difficult Airway Guidelines: an observational survey.
Numerous clinical guidelines are available for management of the unanticipated difficult airway. It is unclear if practice recommendations are endorsed on regional, local, or individual levels. The objective of this observational study was to examine local and regional use of airway guidelines by anesthesiologists within a hospital partnership in Southwestern Ontario. ⋯ Despite widespread awareness of the national CAFG Difficult Airway Guidelines, they are not widely adopted in clinical practice. Further research is warranted to explore barriers to adoption of airway management guidelines for both individual anesthesiologists and anesthesia departments.
-
Flexible bronchoscope-guided tracheal intubation through supraglottic airway devices (SGAs) is a well-established element of difficult intubation algorithms. Success can be limited by dimensional incompatibilities between tracheal tubes (TTs) and SGAs. ⋯ Clinically relevant combinations of adult-size TTs and SGAs can be incompatible, rendering flexible bronchoscope-guided tracheal intubation through an SGA impossible. Additional limitations exist regarding removal of the SGA and maneuverability of the flexible bronchoscope.
-
Since the last Canadian Airway Focus Group (CAFG) guidelines were published in 2013, the published airway management literature has expanded substantially. The CAFG therefore re-convened to examine this literature and update practice recommendations. This second of two articles addresses airway evaluation, decision-making, and safe implementation of an airway management strategy when difficulty is anticipated. ⋯ Prior to airway management, a documented strategy should be formulated for every patient, based on airway evaluation. Bedside examination should seek predictors of difficulty with face-mask ventilation (FMV), tracheal intubation using video- or direct laryngoscopy (VL or DL), supraglottic airway use, as well as emergency front of neck airway access. Patient physiology and contextual issues should also be assessed. Predicted difficulty should prompt careful decision-making on how most safely to proceed with airway management. Awake tracheal intubation may provide an extra margin of safety when impossible VL or DL is predicted, when difficulty is predicted with more than one mode of airway management (e.g., tracheal intubation and FMV), or when predicted difficulty coincides with significant physiologic or contextual issues. If managing the patient after the induction of general anesthesia despite predicted difficulty, team briefing should include triggers for moving from one technique to the next, expert assistance should be sourced, and required equipment should be present. Unanticipated difficulty with airway management can always occur, so the airway manager should have a strategy for difficulty occurring in every patient, and the institution must make difficult airway equipment readily available. Tracheal extubation of the at-risk patient must also be carefully planned, including assessment of the patient's tolerance for withdrawal of airway support and whether re-intubation might be difficult.