The Journal of arthroplasty
-
Randomized Controlled Trial
Incisional Negative Pressure Wound Therapy Devices Improve Short-Term Wound Complications, but Not Long-Term Infection Rate Following Hip and Knee Arthroplasty.
The potential value of incisional negative pressure wound therapy (iNPWT) on lower extremity total joint arthroplasty (TJA) wound healing has been supported in a few retrospective studies. We performed this prospective, randomized, controlled trial to assess the impact of iNPWT on wound appearance, early complications, and late infection rates following hip and knee TJA compared with a standard surgical dressing. ⋯ Our study findings support improved soft tissue healing response with the use of iNPWT devices. While postoperative wound drainage may limit their value following total hip arthroplasty, incisional NPWT devices may have a targeted benefit for elective total knee arthroplasty patients with a body mass index > 35 kg/m2. Specific study in this higher-risk patient group may be helpful to define the value of iNPWT.