Journal of Korean medical science
-
J. Korean Med. Sci. · Nov 2011
Spirometric standards for healthy children and adolescents of Korean Chinese in northeast China.
In China there are 1,923,842 Korean Chinese, who live mostly (92.27%) in the country's three northeast provinces. In spite of this sizeable number, no spirometric data are available at present on them. The present study investigated normal spirometric reference values for the Korean Chinese children and adolescents. ⋯ The predicted values of FVC and FEV1 were higher than values obtained by using Caucasian and other Asian equations (P < 0.001). A set of spirometric reference equations has been derived using a relatively large, healthy, non-smoking young Korean Chinese population with a wide range of ages and heights, the results of which differ from those gained from several other reference equations. These reference equations should be used for evaluation of lung function in this population.
-
J. Korean Med. Sci. · Nov 2011
Calculation of the cardiothoracic ratio from portable anteroposterior chest radiography.
Cardiothoracic ratio (CTR), the ratio of cardiac diameter (CD) to thoracic diameter (TD), is a useful screening method to detect cardiomegaly, but is reliable only on posteroanterior chest radiography (chest PA). We performed this cross-sectional 3-phase study to establish reliable CTR from anteroposterior chest radiography (chest AP). First, CD(Chest PA)/CD(Chest AP) ratios were determined at different radiation distances by manipulating chest computed tomography to simulate chest PA and AP. ⋯ Its sensitivity and specificity was 61% and 54%. In summary, reliable CTR can be calculated from chest AP with an available previous chest PA. This might help physicians detect congestive cardiomegaly for patients undergoing portable chest AP.
-
J. Korean Med. Sci. · Nov 2011
Orthopedic surgeon's awareness can improve osteoporosis treatment following hip fracture: a prospective cohort study.
Through retrospective Jeju-cohort study at 2005, we found low rates of detection of osteoporosis (20.1%) and medication for osteoporosis (15.5%) in those who experienced hip fracture. This study was to determine the orthopedic surgeons' awareness could increase the osteoporosis treatment rate after a hip fracture and the patient barriers to osteoporosis management. We prospectively followed 208 patients older than 50 yr who were enrolled for hip fractures during 2007 in Jeju-cohort. ⋯ According to the questionnaire, the most common barrier to treatment for osteoporosis after a hip fracture was patients reluctance. The detection and medication rate for osteoporosis after hip fracture increased twofold after orthopedic surgeons had attended the intervention program. Nevertheless, the osteoporosis treatment rate remains inadequate.
-
J. Korean Med. Sci. · Nov 2011
Comparative StudyDifferent clinical characteristics among Aeromonas hydrophila, Aeromonas veronii biovar sobria and Aeromonas caviae monomicrobial bacteremia.
This study aimed to compare the clinical presentations of Aeromonas hydrophila, A. veronii biovar sobria and A. caviae monomicrobial bacteremia by a retrospective method at three hospitals in Taiwan during an 8-yr period. There were 87 patients with A. hydrophila bacteremia, 45 with A. veronii biovar sobria bacteremia and 22 with A. caviae bacteremia. Compared with A. hydrophila and A. veronii biovar sobria bacteremia, A. caviae bacteremia was more healthcare-associated (45 vs 30 and 16%; P = 0.031). ⋯ The APACHE II scores of A. caviae bacteremias were lower than A. hydrophila bacteremia and A. veronii biovar sobria bacteremia (7 vs 14 and 16 points; P = 0.002). In conclusion, the clinical presentation of A. caviae bacteremia was much different from A. hydrophila and A. veronii biovar sobria bacteremia. The severity and mortality of A. caviae bacteremia were lower than A. hydrophila or A. veronii biovar sobria bacteremia.
-
We developed the standard digital images (SDIs) to be used in the classification and recognition of pneumoconiosis. From July 3, 2006 through August 31, 2007, 531 retired male workers exposed to inorganic dust were examined by digital (DR) and analog radiography (AR) on the same day, after being approved by our institutional review board and obtaining informed consent from all participants. All images were twice classified according to the International Labour Office (ILO) 2000 guidelines with reference to ILO standard analog radiographs (SARs) by four chest radiologists. ⋯ Twenty-one of 29 symbols were present except cp, ef, ho, id, me, pa, ra, and rp. A set of 120 SDIs had more various pneumoconiosis findings than ILO SARs that were developed from adequate methods. It can be used as digital reference images for the recognition and classification of pneumoconiosis.