Journal of voice : official journal of the Voice Foundation
-
The aims of this study were to examine vowel and gender effects on jitter and shimmer in a typical clinical voice task while correcting for the confounding effects of voice sound pressure level (SPL) and fundamental frequency (F(0)). Furthermore the relative effect sizes of vowel, gender, voice SPL, and F(0) were assessed, and recommendations for clinical measurements were derived. With this cross-sectional single cohort study, 57 healthy adults (28 women, 29 men) aged 20-40 years were investigated. ⋯ Phonations at a predefined voice SPL (80 dB minimum) and vowel (/a/) would enhance measurement reliability. Furthermore, gender-specific thresholds applying these guidelines should be established. However, the efficiency of these measures should be verified and tested with patients.