Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
-
J Am Soc Echocardiogr · May 2014
Review Meta AnalysisNormal ranges of right ventricular systolic and diastolic strain measures in children: a systematic review and meta-analysis.
Establishment of the range of normal values and associated variations of two-dimensional (2D) speckle-tracking echocardiography (STE)-derived right ventricular (RV) strain is a prerequisite for its routine clinical application in children. The objectives of this study were to perform a meta-analysis of normal ranges of RV longitudinal strain measurements derived by 2D STE in children and to identify confounders that may contribute to differences in reported measures. ⋯ This study is the first to define normal values of 2D STE-derived RV strain in children on the basis of a meta-analysis. The normal mean value in children for RV global strain is -29.03% (95% CI, -31.52% to -26.54%). The normal mean value for RV global systolic strain rate is -1.88 sec(-1) (95% CI, -2.10 to -1.59 sec(-1)). RV segmental strain has a stable base-to-apex gradient that highlights the dominance of deep longitudinal layers of the right ventricle that are aligned base to apex. Variations among different normal ranges did not appear to be dependent on differences in demographic, clinical, or equipment parameters in this meta-analysis. All of the eligible studies used equipment and software from one manufacturer (GE Healthcare).