Clinical evaluation of a new multiparameter neuromonitoring device: measurement of brain tissue oxygen, brain temperature, and intracranial pressure.
The study presented evaluated the first clinical use of a new multiparameter catheter measuring intracranial pressure (ICP), partial pressure of brain tissue oxygen (ptiO2), and brain temperature (TBr) (Neurovent PTO). To assess the validity of measured ptiO2 a second probe, which represents the current golden standard of ptiO2 measurement, was implanted (Licox system). ⋯ Combining 3 different neuromonitoring functions in 1 probe might ease monitoring by making a second (ptiO2) probe unnecessary. Interpretation of our data is limited by several factors: (1) monocentric study; (2) reduced mechanical probe stability, handling difficulties with the double lumen bolt; (3) design changes to improve mechanical stability will require further study; (4) conflict of interest with Raumedic because of its support for the study. The conclusion drawn from our study is that the new multiparameter probe evaluated does measure ICP, TBr, and ptiO2. But all the initial data given in this paper have to be interpreted cautiously. A new study will be necessary when the mechanical stability of the new probe has been improved.
-
The 2008 literature contained numerous articles of interest to physicians providing perioperative care for neurosurgical or neurologically-impaired patients. In this review, we provide a brief summary of common themes and unique or novel reports. Topics addressed are intracranial hemorrhage, traumatic brain injury, neuropharmacology, neuroprotection, spine surgery, and treatment of carotid artery atherosclerotic disease.
-
J Neurosurg Anesthesiol · Apr 2009
Randomized Controlled TrialEEG entropy values during isoflurane, sevoflurane and halothane anesthesia with and without nitrous oxide.
We hypothesized that like bispectral index, entropy may be anesthetic agent specific. We carried out a study to assess the entropy values of different anesthetics at equi-minimal alveolar concentrations (MACs) with air and nitrous oxide as carrier gases. Thirty adult patients undergoing spine surgery were randomized to receive halothane, isoflurane, or sevoflurane, in 2 stages, (a) with air/oxygen mixture (2:1) and (b) in nitrous oxide/oxygen (2:1). ⋯ At 1.5 MAC for all agents, after addition of nitrous oxide, there was an insignificant reduction in both RE and SE (P>0.05). Again the values of RE and SE remained high for halothane as compared with isoflurane and sevoflurane. In conclusion, our data suggest a possibility of misinterpretation of anesthetic hypnosis when entropy values increase with addition of nitrous oxide to 1 MAC isoflurane and sevoflurane.