NMR in biomedicine
-
Quantitative susceptibility mapping is a potentially powerful technique for mapping tissue magnetic susceptibility from gradient recalled echo (GRE) MRI signal phase. In this review, we present up-to-date theoretical developments in analyzing the relationships between GRE signal phase and the underlying tissue microstructure and magnetic susceptibility at the cellular level. Two important phenomena contributing to the GRE signal phase are at the focus of this review - tissue structural anisotropy (e.g. cylindrical axonal bundles in white matter) and magnetic susceptibility anisotropy. ⋯ While the components of χ^ are compartmental susceptibilities "weighted" by their volume fractions, the components of L^ are weighted by specific numerical factors depending on tissue geometrical microsymmetry. In multi-compartment structures, the components of the Lorentzian tensor also depend on the compartmental relaxation properties, hence the MR pulse sequence settings. Copyright © 2016 John Wiley & Sons, Ltd.
-
Quantitative susceptibility mapping (QSM) measures tissue magnetic susceptibility and typically relies on time-consuming three-dimensional (3D) gradient-echo (GRE) MRI. Recent studies have shown that two-dimensional (2D) multi-slice gradient-echo echo-planar imaging (GRE-EPI), which is commonly used in functional MRI (fMRI) and other dynamic imaging techniques, can also be used to produce data suitable for QSM with much shorter scan times. However, the production of high-quality QSM maps is difficult because data obtained by 2D multi-slice scans often have phase inconsistencies across adjacent slices and strong susceptibility field gradients near air-tissue interfaces. ⋯ The experimental results show that this new 2D EPI-based QSM technique can produce quantitative susceptibility measures that are comparable with those of 3D GRE-based QSM across different brain regions (e.g. subcortical iron-rich gray matter, cortical gray and white matter). This new 2D EPI QSM reconstruction method is implemented within STI Suite, which is a comprehensive shareware for susceptibility imaging and quantification. Copyright © 2016 John Wiley & Sons, Ltd.
-
Review Comparative Study
An illustrated comparison of processing methods for phase MRI and QSM: removal of background field contributions from sources outside the region of interest.
The elimination of so-called background fields is an essential step in phase MRI and quantitative susceptibility mapping (QSM). Background fields, which are caused by sources outside the region of interest (ROI), are often one to two orders of magnitude stronger than tissue-related field variations from within the ROI, hampering quantitative interpretation of field maps. ⋯ We discuss the basic theoretical foundations and derive fundamental limitations of background field elimination. Copyright © 2016 John Wiley & Sons, Ltd.
-
Sophisticated harmonic artifact reduction for phase data (SHARP) is a method to remove background field contributions in MRI phase images, which is an essential processing step for quantitative susceptibility mapping (QSM). To perform SHARP, a spherical kernel radius and a regularization parameter need to be defined. In this study, we carried out an extensive analysis of the effect of these two parameters on the corrected phase images and on the reconstructed susceptibility maps. ⋯ We demonstrated and confirmed the new parameter scheme in vivo. The novel regularization scheme allows the use of the same regularization parameter irrespective of other imaging parameters, such as image resolution. Copyright © 2016 John Wiley & Sons, Ltd.
-
Standard functional MRI (fMRI), which includes resting-state or paradigm-driven designs, is widely used in studies of brain function, aging, and disease. These fMRI studies typically use two-dimensional gradient echo-planar imaging, which inherently contains phase data that enables quantitative susceptibility mapping (QSM). This work focuses on the dual value of QSM within fMRI studies, by providing both a localized analysis of functional changes in activated tissue, and iron-sensitive structural maps in deep grey matter (DGM). ⋯ Mean-level DGM QSM of the time series was successfully extracted in all cases, while fQSM results were more prone to residual background fields and showed less functional change compared with standard magnitude fMRI. Under the conditions prescribed, standard fMRI studies may be used for robust mean-level DGM QSM, enabling study of DGM iron accumulation, in addition to functional analysis. Copyright © 2016 John Wiley & Sons, Ltd.