Archives of orthopaedic and trauma surgery
-
Arch Orthop Trauma Surg · Mar 2020
ReviewAcetabular custom-made implants for severe acetabular bone defect in revision total hip arthroplasty: a systematic review of the literature.
The management of acetabular bone loss is a challenging problem in revision total hip arthroplasty (rTHA). The aim of this systematic review is to summarize and critically analyze indications, complications, clinical and radiological outcomes of custom-made acetabular components in rTHA. ⋯ The acetabular custom-made implants represent a reliable solution for pelvic discontinuity and particular cases of bone loss classified as Paprosky Type IIIA-B or type III-IV according to American Academy of Orthopaedic Surgeons system where the feature of the defect cannot be handled with standard implants. This strategy allows to fit the implant to the residual host bone, bypassing the bony deficiency and restoring hip biomechanics. Satisfactory clinical and radiological outcomes at mid-term follow-up are reported in literature.
-
Arch Orthop Trauma Surg · Mar 2020
A two-portal technique using a flexible reamer system is a safe and effective method for transportal anterior cruciate ligament reconstruction.
A flexible reamer system (FRS) for transportal anterior cruciate ligament reconstruction (ACLR) has been developed to overcome the technical challenges of a rigid reamer system. The purpose of this study was to investigate the safety and effectiveness of the two-portal technique using an FRS by evaluating femoral tunnel geometry. ⋯ Retrospective case series; level of evidence, 4.
-
Arch Orthop Trauma Surg · Mar 2020
Correction to: Ex situ reconstruction of comminuted radial head fractures: is it truly worth a try?
The original version of this article unfortunately contained a mistake.
-
Arch Orthop Trauma Surg · Mar 2020
Optimal rotational positioning of tibial component in total knee arthroplasty: determined by linker surgical technique using a high definition CT.
The rotational alignment of femoral and tibial components is an important determinant of the success of Total Knee Arthroplasty (TKA). The optimal rotational position of the tibial component is still unclear. The purpose of this study was (1) to determine the pre-operative S-TEA (surgical-transepicondylar axis) derived tibialanteroposterior (AP) axis angle and postoperative tibial component axis angle using a "Bird's eye" high-definition CT image in TKA performed by Linker surgical technique; (2) to determine the femorotibial mismatch angle; and (3) to determine the optimal tibial component rotation in a well-aligned femoral and tibial components. ⋯ Level II.
-
Arch Orthop Trauma Surg · Mar 2020
Inducing life-like distal radius fractures in human cadaveric specimens: a tool for enhanced surgical training.
Surgical education consists often times of a discrepancy between necessary amount of provided operative teaching and amount of organizational and ward duties. Operative education is often cut to a minimum. As public awareness toward surgical competence raises, so must the educational system. Courses that provide pre-fractured cadaveric specimens can facilitate surgical teaching realistically, prior to operating on living patients. The aim of this study is to introduce a realistic distal radius fracture simulation setup. ⋯ A high energetic impulse induced by a custom-made drop-test bench can successfully simulate realistic distal radius fractures in cadaveric specimens with intact soft tissue. Furthermore, these pre-fractured specimens can be utilized in surgical education to provide a teaching experience as realistic as possible without harming living patients.