Archives of orthopaedic and trauma surgery
-
Arch Orthop Trauma Surg · Dec 2021
A ligament tensor-guided extramedullary alignment technique for distal femoral cut in total knee replacement: results at a minimum 3 years follow-up.
Femoral intramedullary canal referencing is used by most knee arthroplasty systems for distal femoral cut; to avoid the opening of the femoral canal different solutions have been presented such as navigation, patient-specific instruments (PSI) or the use of an extramedullary device. The FuZion® system is a tensor device, created to merge the two main techniques for performing a total knee arthroplasty: the ligament balancing and measured resection techniques. Our idea was to use the tensor as an extramedullary cutting guide for the distal femoral cut, based on a 90° tibial resection. ⋯ This technique for performing a ligament driven alignment in total knee arthroplasty showed encouraging clinical outcomes at mid-term follow up leaving a residual deformity on the coronal plane.
-
The concept of custom total knee arthroplasty (TKA) is explored with specific attention to current limitations. Arguments in favor of custom TKA are the anatomic and functional variability we encounter in our patients. The biggest conceptual challenge is to marry the need for correction of deformity with the ambition to stay as close as possible to original anatomy. ⋯ Custom knee implants are the next step in matching the geometric features of the prosthesis to the anatomy of the individual patient, after several iterations that added asymmetry and sizes in the existing implants. Several companies have proven that it is feasible to produce these implants in a safe way. An overview of current literature reveals the lack of strong methodological studies that prove the value of this new technology. Custom knee implants face conceptual and practical difficulties, some of which might be overcome with technological advances, such as robotics and artificial intelligence.
-
The Mako robotic arm knee arthroplasty system was initially indicated in unicompartmental knee arthroplasty followed by bicompartmental and total knee arthroplasty techniques. The system utilizes three elements: (1) Pre-op 3D CT based planning and image based intra-op navigation. (2) Pre-resection implant modifications with integrated alignment, implant position and gap data, and (3) A semi-constrained robotic arm assisted execution of bone resection with "haptic" boundaries, and cemented implants. ⋯ The MAKO robotic system can assist the surgeon with anatomic landmarks, provides the flexibility for independent gap balance through implant and alignment refinement, and three-dimensional soft tissue balancing data to achieve functional stability. Registry data has shown improved outcome survivorship irrespective of the surgeons' volumes and learning curves.
-
Arch Orthop Trauma Surg · Dec 2021
Immersive virtual reality enables technical skill acquisition for scrub nurses in complex revision total knee arthroplasty.
Immersive Virtual Reality (iVR) is a novel technology which can enhance surgical training in a virtual environment without supervision. However, it is untested for the training to select, assemble and deliver instrumentation in orthopaedic surgery-typically performed by scrub nurses. This study investigates the impact of an iVR curriculum on this facet of the technically demanding revision total knee arthroplasty. ⋯ For scrub nurses, unfamiliarity with complex surgical procedures or equipment is common. Immersive VR training improved their understanding, technical skills and efficiency. These iVR-learnt skills transferred into the real world.
-
Arch Orthop Trauma Surg · Dec 2021
ReviewAssistive technologies in knee arthroplasty: fashion or evolution? Rate of publications and national registries prove the Scott Parabola wrong.
Most opponents of assistive technologies in orthopedic surgery consider them as a marketing ruse or fashion. Our hypothesis was that many innovations in modern knee arthroplasty are not following the Scott Parabola. This parabola represents the visual curve of a procedure or therapy showing great promise at the beginning, becoming the standard treatment after reports of encouraging results, only to fall into disuse due to adverse outcome reports. This study aimed to assess the interest in these assistive technologies by (1) their number of publications/year and (2) their actual surgical use reported in the National Joint Registries. ⋯ Most of the innovations in modern knee arthroplasty are not following the Scott Parabola. After a fast rise, these techniques do not disappear but continue to evolve. Their evolution is synergistic, and techniques appeared to be linked to each other's. Despite persisting concerns about the cost-efficiency of assisting technologies in knee arthroplasties, the interest and use do not decrease and seems to be directly linked to an exponential increase in interest for a better understanding of alignment targets and improved functional recovery.