Archives of orthopaedic and trauma surgery
-
Arch Orthop Trauma Surg · Dec 2021
Robotics improves alignment accuracy and reduces early revision rates for UKA in the hands of low-volume UKA surgeons.
It is known that in uni-compartmental knee arthroplasty (UKA) low-volume surgeons have a higher complication and revision rate than high-volume surgeons. Further, robotic-assisted UKA leads to lower early revision rate as well as fewer limb and joint line outliers compared to conventional UKA. The purpose of this study was to retrospectively analyze the outliers' and revision rate of low-volume UKA surgeons with different robotic systems at short-term follow-up. ⋯ Robotic-assisted UKA is a safe procedure in the hand of low-volume UKA surgeons. Robotic-assisted UKA minimizes overcorrection into valgus mal-alignment. Low revision rates are observed at short-term follow-up for robotic-assisted UKA. The choice of the different robotic systems has no impact on the outcome.
-
Arch Orthop Trauma Surg · Dec 2021
Immersive technologies for total knee arthroplasty surgical education.
The need to adapt surgical curricula to meet the demands of an increasingly restrictive training environment is rising. Modern constraints of surgical trainees including work-hour restrictions and concerns surrounding patient safety have created an opportunity to supplement traditional teaching methods with developing immersive technologies including virtual and augmented reality. Virtual reality (VR) and augmented reality (AR) have been preliminarily investigated as it relates to total joint arthroplasty. The purpose of this article is to discuss VR and AR as it applies to modern total knee replacement (TKR) surgical education.
-
Arch Orthop Trauma Surg · Dec 2021
Joint line is restored in robotic-arm-assisted total knee arthroplasty performed with a tibia-based functional alignment.
Functional alignment (FA) in total knee arthroplasty (TKA) has been introduced to restore the native joint line obliquity, respect the joint line height and minimize the need of soft tissue releases. The purpose of this study was to assess the intraoperative joint line alignment and compare it with the preoperative epiphyseal orientation of the femur and tibia in patients undergoing robotic-arm-assisted (RA)-TKA using FA. ⋯ The proposed robotic-assisted functional technique for TKA alignment, with a restricted tibial component coronal alignment, based on the preoperative phenotype and femoral component positioning as dictated by the soft tissues, provided joint line respecting resections. Further studies are needed to assess long-term implant survivorship, patient satisfaction and alignment-related failures.
-
Arch Orthop Trauma Surg · Dec 2021
An insert with less than spherical medial conformity causes a loss of passive internal rotation after calipered kinematically aligned TKA.
In total knee arthroplasty (TKA), the level of conformity, a medial stabilized (MS) implant, needs to restore native (i.e., healthy) knee kinematics without over-tensioning the flexion space when the surgeon chooses to retain the posterior cruciate ligament (PCL) is unknown. Whether an insert with a medial ball-in-socket conformity and lateral flat surface like the native knee or a less than spherical medial conformity restores higher and closer to native internal tibial rotation without anterior lift-off, an over-tension indicator, when implanted with calipered kinematic alignment (KA), is unknown. ⋯ An MS insert with a medial ball-in-socket and lateral flat surface that matches the native knee's spherical conformity restores native tibial internal rotation when implanted with calipered KA and PCL retention without over-tensioning the flexion space.
-
Arch Orthop Trauma Surg · Dec 2021
Intraoperative virtual reality distraction in TKA under spinal anesthesia: a preliminary study.
The effect of patient anxiety during the perioperative period has been shown to be of great importance in its influence on post-operative recovery. Over the last 10 years, virtual reality (VR) has been developed in anesthesia for patient's distraction by immersion. The aim of this study was to evaluate post-operative patient anxiety the day after TKA surgery under spinal anesthesia (SA) with or without VR distraction. ⋯ Using VR for immersive distraction seemed to lead to no difference in patient anxiety in TKA under SA. Intra-operative adverse events were decreased, and post-operative comfort was increased. Patient satisfaction was not modified. This preliminary study is encouraging and gives us arguments to involve larger number of patients while exploring the various possibilities offered by VR.