Is low compression pressure able to improve venous pumping function in patients with venous insufficiency?
A too high resting pressure of compression devices is poorly tolerated and may cause skin defects, especially in patients with concomitant arterial occlusive disease. ⋯ In patients with venous pumping failure, inelastic bandages produce a significant pressure-dependent increase of EF. A significant improvement in venous pumping function was achieved with inelastic bandages even at a resting pressure of 20 mmHg.