Journal of magnetic resonance imaging : JMRI
-
J Magn Reson Imaging · May 2008
Comparative StudyA tracking-based diffusion tensor imaging segmentation method for the detection of diffusion-related changes of the cervical spinal cord with aging.
To compare region of interest (ROI)-based and diffusion tensor tractography (DTT)-based methods for evaluating diffusion properties of the spinal cord as a function of age. ⋯ DTT is a robust and reproducible technique to segment the voxels of interest in the spinal cord.
-
J Magn Reson Imaging · May 2008
Water excitation MPRAGE: an alternative sequence for postcontrast imaging of the abdomen in noncooperative patients at 1.5 Tesla and 3.0 Tesla MRI.
To evaluate the diagnostic image quality of postgadolinium water excitation-magnetization-prepared rapid gradient-echo (WE-MPRAGE) sequence in abdominal examinations of noncooperative patients at 1.5 Tesla (T) and 3.0T MRI. ⋯ WE-MPRAGE may be used as a T1-weighted postgadolinium fat-attenuated sequence in noncooperative patients, particularly at 3.0T MRI.
-
J Magn Reson Imaging · May 2008
Gadolinium-based contrast agents and their potential role in the pathogenesis of nephrogenic systemic fibrosis: the role of excess ligand.
To investigate the role of excess ligand present in gadolinium (Gd) -based contrast agents in the development of nephrogenic systemic fibrosis (NSF). Using a dosing regimen to simulate the exposure seen in patients with severe renal impairment, we investigated the effect of excess ligand on Gd-deposition and the depletion of endogenous ions. ⋯ Our findings suggest that there is an inverse correlation between the amount of excess ligand present in Gd-containing contrast agents and the amount of Gd in the tissue, and further underline the importance of the inherent stability of these agents in the development of NSF.
-
To track three-dimensional (3D) myocardial tissue motion using slice followed cine displacement encoded imaging with stimulated echoes (DENSE). ⋯ Slice followed cine DENSE provides an accurate method for 3D tissue tracking.
-
J Magn Reson Imaging · May 2008
Comparative StudySingle-breathhold four-dimensional assessment of left ventricular volumes and function using k-t BLAST after application of extracellular contrast agent at 3 Tesla.
To prospectively determine the feasibility and accuracy of a four-dimensional (4D) k-space over time broad-use linear acquisition speed-up technique (k-t BLAST) for the evaluation of left ventricular (LV) volumes in comparison to standard multiple-breathhold cine imaging, using a 3.0 Tesla (3T) MR system. ⋯ The use of the single-breathhold 4D k-t BLAST technique for the assessment of LV volume is feasible and accurate in 3T MRI.