International journal of obstetric anesthesia
-
Int J Obstet Anesth · May 2016
Case ReportsEarly postpartum mitral valve thrombosis requiring extra corporeal membrane oxygenation before successful valve replacement.
Pregnancy is associated with an increased risk of thrombosis in women with mechanical prosthetic heart valves. We present the case of a 29-year-old woman who developed early postpartum mitral valve thrombus after an elective cesarean delivery. The patient had a mechanical mitral valve and was treated with warfarin in the second trimester, which was replaced with high-dose dalteparin during late pregnancy. ⋯ Transesophageal echocardiography revealed a mitral valve thrombus. The patient underwent a successful mitral valve replacement after three days on extra corporeal membrane oxygenation. This case highlights the importance of multidisciplinary care and frequent monitoring of anticoagulation during care of pregnant women with prosthetic heart valves.
-
Int J Obstet Anesth · May 2016
Letter Case ReportsSevere compression of the inferior vena cava during cesarean section.