Randomized Controlled TrialScrew augmentation reduces motion at the bone-implant interface: a biomechanical study of locking plate fixation of proximal humeral fractures.
Shear forces at the bone-implant interface lead to a loss of reduction after locking plate fixation of proximal humeral fractures. The aim of the study was to analyze the roles of medial support screws and screw augmentation in failure loads and motion at the bone-implant interface after locking plate fixation of proximal humeral fractures. ⋯ The addition of bone cement to augment anteriorly directed head screws does not increase stiffness and failure loads but reduces motion at the bone-implant interface. Thus, the risk of secondary dislocation of the head fragment may be reduced.