Journal of shoulder and elbow surgery
-
J Shoulder Elbow Surg · Dec 2017
Randomized Controlled TrialRadiographic and clinical comparison of pegged and keeled glenoid components using modern cementing techniques: midterm results of a prospective randomized study.
Glenoid component loosening remains a significant issue after anatomic shoulder arthroplasty. Pegged glenoid components have shown better lucency rates than keeled components in the short term; however, midterm to long-term results have not fully been determined. We previously reported early outcomes of the current randomized controlled group of patients, with higher glenoid lucency rates in those with a keeled glenoid. The purpose of this study was to evaluate the radiographic and clinical outcomes of these components at minimum 5-year follow-up. ⋯ At an average 7.9-year follow-up, non-ingrowth, all-polyethylene pegged glenoid implants are equivalent to keeled implants with respect to radiolucency, clinical outcomes, and need for revision surgery.