Paediatric anaesthesia
-
Paediatric anaesthesia · Sep 2017
A Visual Analog Scale to assess anxiety in children during anesthesia induction (VAS-I): Results supporting its validity in a sample of day care surgery patients.
The modified Yale Preoperative Anxiety Scale is widely used to assess children's anxiety during induction of anesthesia, but requires training and its administration is time-consuming. A Visual Analog Scale, in contrast, requires no training, is easy-to-use and quickly completed. ⋯ The present data provide preliminary data for the validity of a Visual Analog Scale to assess children's anxiety during induction.
-
Paediatric anaesthesia · Sep 2017
Impact of anesthesiologists on parental perioperative satisfaction scores.
While the focus on patient experience as an important outcome has significantly increased over the past decade, there is paucity of data on predictive factors associated with parental recommendation of a surgical facility to friends and family. ⋯ Parental recommendation of a surgical facility to friends and family depends on a number of variables with the quality of perioperative communication with the anesthesiologist being the most predictive item.
-
Paediatric anaesthesia · Sep 2017
Breathing circuit compliance and accuracy of displayed tidal volume during pressure-controlled ventilation of infants: A quality improvement project.
Anesthesia machines have evolved to deliver desired tidal volumes more accurately by measuring breathing circuit compliance during a preuse self-test and then incorporating the compliance value when calculating expired tidal volume. The initial compliance value is utilized in tidal volume calculation regardless of whether the actual compliance of the breathing circuit changes during a case, as happens when corrugated circuit tubing is manually expanded after the preuse self-test but before patient use. We noticed that the anesthesia machine preuse self-test was usually performed on nonexpanded pediatric circuit tubing, and then the breathing circuit was subsequently expanded for clinical use. We aimed to demonstrate that performing the preuse self-test in that manner could lead to incorrectly displayed tidal volume on the anesthesia machine monitor. The goal of this quality improvement project was to change the usual practice and improve the accuracy of displayed tidal volume in infants undergoing general anesthesia. ⋯ Performing a preuse self-test on a nonexpanded pediatric circuit that is then expanded leads to falsely elevated displayed tidal volume in infants less than 10 kg during pressure-controlled ventilation. Overestimation of reported tidal volume can be avoided by expanding the breathing circuit tubing to the length which will be used during a case prior to performing the anesthesia machine preuse self-test. After department-wide education and implementation, performing a correct preuse self-test is now the standard practice in our cardiac operating rooms.
-
Paediatric anaesthesia · Sep 2017
Impact of endotracheal tube shortening on work of breathing in neonatal and pediatric in vitro lung models.
Work of breathing accounts for a significant proportion of total oxygen consumption in neonates and infants. Endotracheal tube inner diameter and length significantly affect airflow resistance and thus work of breathing. While endotracheal tube shortening reduces endotracheal tube resistance, the impact on work of breathing in mechanically ventilated neonates and infants remains unknown. ⋯ In this in vitro lung model, endotracheal tube shortening had minimal effects on work of breathing. Moreover, the calculated percentage reduction of the total daily energy demand after endotracheal tube shortening was minimal.