European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
Comparative Study
Anterior lumbar interbody fusion: does stable anterior fixation matter?
The purpose of this study was to compare the outcome of anterior lumbar interbody fusion without instrumentation (uninstrumented ALIF) against that with stable anterior cage fixation using Hartshill horseshoe instrumentation (ALIF-HH) for similar severity of disc disease. Between April 1994 and June 1998 the senior author N. R. ⋯ On subjective score assessment, there was a satisfactory outcome (score=30) of 87.5% (21 patients) in the uninstrumented ALIF group and 85.2% (23 patients) in the ALIF-HH group ( P>0.05). On classification by the Oswestry Index into four categories, we found no difference in outcome between the two groups: 83.3% ( n=20) had a satisfactory outcome (defined as Excellent or Better) with ALIF and 77.8% ( n=21) had a satisfactory outcome with ALIF-HH using the Oswestry Disability Index for post-operative assessment ( P>0.05). The results of this study indicate that the Hartshill horseshoe cage does improve the fusion rate, but does not affect clinical outcome.
-
Pseudarthrosis remains a significant problem in spinal fusion. The objective of our study was to investigate the effects of autologous growth factors (AGF) in instrumented transforaminal lumbar interbody spinal fusion (TLIF). A prospective review was carried out of 23 patients who underwent TLIF with application of AGF, with a minimum 2-year follow-up. ⋯ Excluding the cases with pseudarthrosis, there was faster bony healing in patients who had been treated with AGF application. This study indicates that although AGF may demonstrate faster fusions, it does not result in an overall increase in spinal fusion rates. Further studies are needed before AGF can routinely be used as an adjunct in spinal fusion.
-
In a prospective cohort study in 94 patients with 3 years' follow-up the efficacy of rigid and semi-rigid transpedicular instrumentation for lumbar spine fusion was evaluated via three established scores. Patient groups were similar in respect of anthropometric data. ⋯ Selecting implant rigidity on these criteria led to results with an improvement rate well within the upper success range reported in the literature. Among people in employment, a lengthy preoperative sick leave was an important predictor for unsatisfactory outcome.
-
Comparative Study
Comparison of plain radiographs with CT scan to evaluate interbody fusion following the use of titanium interbody cages and transpedicular instrumentation.
The availability of lumbar interbody cages has fuelled renewed interest in interbody fusion. Despite this, there is no consensus regarding the best non-invasive method for evaluation of interbody fusion, especially where cages have been used. The purpose of this study was to determine whether high-quality thin-slice (1- to 3-mm) computed tomography (CT) scans allow proper evaluation of interbody fusion through titanium cages. ⋯ Radiographs also failed to demonstrate all the loose cages. The results of the study show that high-quality CT scans show images suggesting bridging bony trabeculae following the use of titanium interbody cages. They also appear to show consistent bone outside the cages in spite of no bone graft having been used, and they appear to be better than plain radiographs in the early detection of cage loosening.