European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
This study evaluates the clinical and radiological results of using the facet screw fixation technique described by Boucher in combination with a posterolateral fusion rather than a posterior fusion for symptomatic degenerative disease of the lumbosacral junction. It is a retrospective review of 38 consecutive patients with an average follow-up of 28 months. Radiologically, all patients had a solid fusion. ⋯ There were no neurological complications. The findings support the view that the Boucher technique of facet joint fixation in combination with a posterolateral fusion is a safe and effective method of dealing with chronic symptoms relating to degenerative changes at the lumbosacral junction. The authors stress the importance of patient selection and attention to operative technique if the clinical results are to correlate with the results of fusion.
-
Randomized Controlled Trial Clinical Trial
Outcome of the Graf ligamentoplasty procedure compared with anterior lumbar interbody fusion with the Hartshill horseshoe cage.
The objective of our study was to assess the efficacy of Graf ligamentoplasty in comparison with rigid fixation and fusion with the Hartshill horseshoe cage for similar severity of disc degeneration. Although studies have been done on the Graf ligamentoplasty procedure and the Hartshill horseshoe cage, their efficacy has never been compared in any study. This study was done to decide whether retaining mobility and stabilizing the spine is best or stiffening the lumbar segment by fusion is preferable. ⋯ At a minimum follow-up of 2.1 years, we found that 93% of patients who had undergone Graf ligamentoplasty had a satisfactory outcome (rated "excellent" or "better") compared to 77.8% of patients who had been treated with ALIF with Hartshill horseshoe cage stabilization and fusion, when measured on the Oswestry Disability Index ( P<0.05). Retaining mobility in the lumbar segments gives better results after stabilisation with Graf ligaments than rigid fixation and fusion with the Hartshill horseshoe cage in the short term. We will be watching this cohort of patients over the next few years.
-
Pseudarthrosis remains a significant problem in spinal fusion. The objective of our study was to investigate the effects of autologous growth factors (AGF) in instrumented transforaminal lumbar interbody spinal fusion (TLIF). A prospective review was carried out of 23 patients who underwent TLIF with application of AGF, with a minimum 2-year follow-up. ⋯ Excluding the cases with pseudarthrosis, there was faster bony healing in patients who had been treated with AGF application. This study indicates that although AGF may demonstrate faster fusions, it does not result in an overall increase in spinal fusion rates. Further studies are needed before AGF can routinely be used as an adjunct in spinal fusion.
-
Comparative Study
Comparison of plain radiographs with CT scan to evaluate interbody fusion following the use of titanium interbody cages and transpedicular instrumentation.
The availability of lumbar interbody cages has fuelled renewed interest in interbody fusion. Despite this, there is no consensus regarding the best non-invasive method for evaluation of interbody fusion, especially where cages have been used. The purpose of this study was to determine whether high-quality thin-slice (1- to 3-mm) computed tomography (CT) scans allow proper evaluation of interbody fusion through titanium cages. ⋯ Radiographs also failed to demonstrate all the loose cages. The results of the study show that high-quality CT scans show images suggesting bridging bony trabeculae following the use of titanium interbody cages. They also appear to show consistent bone outside the cages in spite of no bone graft having been used, and they appear to be better than plain radiographs in the early detection of cage loosening.
-
In a prospective cohort study in 94 patients with 3 years' follow-up the efficacy of rigid and semi-rigid transpedicular instrumentation for lumbar spine fusion was evaluated via three established scores. Patient groups were similar in respect of anthropometric data. ⋯ Selecting implant rigidity on these criteria led to results with an improvement rate well within the upper success range reported in the literature. Among people in employment, a lengthy preoperative sick leave was an important predictor for unsatisfactory outcome.