European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
Review Case Reports
Surgical treatment of spontaneous intracranial hypotension secondary to degenerative cervical spine pathology: a case report and literature review.
A rare cause of intracranial hypotension is leakage of cerebrospinal fluid (CSF) through a dural breach from degenerative cervical spine pathology. To our knowledge there have been only four cases described in the English literature. Treatment is challenging and varies from case to case, with complete symptom resolution reported for only one patient. Herein we review the literature and describe our surgical management of a 46-year-old woman with symptomatic intracranial hypotension from the penetration of the cervical thecal sac. ⋯ Two months after this novel surgical blood patch procedure the patient was asymptomatic and follow-up imaging demonstrated complete resolution.
-
Description of syrinx resolution after posterior fossa decompression (PFD) in patients with scoliosis secondary to Chiari malformation type I (CMI) and syringomyelia (SM) has been rarely reported in the literature. This study was performed to investigate the outcome of PFD in patients with scoliosis secondary to CMI and to identify potential predictive factors for better outcome after PFD. ⋯ Syringes showed significant improvement after PFD in most patients with scoliosis secondary to CMI. Resolution generally occurred within 6 months follow-up and continued at a slow rate for several years. In addition, the severity of tonsillar descent is a potential predictor for better improvement after standard PFD.
-
When the intervertebral disc is removed to relieve chronic pain, subsequent segment stabilization should restore the functional mechanics of the native disc. Because of partially constrained motions and the lack of intrinsic rotational stiffness ball-on-socket implants present many disadvantages. Composite disc substitutes mimicking healthy disc structures should be able to assume the role expected for a disc substitute with fewer restrictions than ball-on-socket implants. ⋯ All device versions altered the coupled intersegmental shear deformations affecting facet joint contact through contact area displacements. Loads in the bony endplates adjacent to the implants increased as the implant stiffness decreased but did not appear to be a strong limitation for the implant biomechanical and mechanobiological functionality. In conclusion, numerical results given by biomimetic composite disc substitutes were encouraging with greater potential than that offered by ball-on-socket implants.
-
The hypothesis for this study was that the simulated wear behavior of a hydroxyapatite coated, self-mating PEEK cervical disc arthroplasty device would be dependent on the simulated testing environment. ⋯ This study showed that at a time when data from retrieval analyses is deficient, it is important to test the wear resistance of cervical disc arthroplasty devices under various conditions. Long-term clinical results and ongoing implant retrievals are required for validation between clinical performance and simulator inputs.