European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
The projectional nature of radiogram limits its amount of information about the instrumented spine. MRI and CT imaging can be more helpful, using cross-sectional view. However, the presence of metal-related artifacts at both conventional CT and MRI imaging can obscure relevant anatomy and disease. ⋯ However, on MRI imaging metallic implants may produce geometric distortion, the so-called susceptibility artifact. In conclusion, although 140 kV and high milliamperage second exposures are recommended for imaging patients with hardware, caution should always be exercised, particularly in children, young adults, and patients undergoing multiple examinations. MRI artifacts can be minimized by positioning optimally and correctly the examined anatomy part with metallic implants in the magnet and by choosing fast spin-echo sequences, and in some cases also STIR sequences, with an anterior to posterior frequency-encoding direction and the smallest voxel size.
-
Multiple myeloma (MM) is a B cell malignancy characterized by important alterations of physiologic bone turnover, wherein increased osteoclastic bone resorption is not accompanied by a comparable increase in bone formation, resulting in diffuse osteopenia, focal lytic lesions, pathologic fractures, hypercalcemia, and bony pain. Consequently, patients with MM frequently require for quality of life's improvement and pain's treatment radiation therapy, surgery, and analgesic medication. Minimally invasive surgical procedures such as the kyphoplasty allows patients with pathological osteolytic vertebral lesions to have immediate improvement in their quality of life. ⋯ Segmental kyphosis angle correction showed a mean decrease of 1.7 degrees (range 0 degrees -2.5 degrees ) at radiographic control at 5-year follow-up, with respect to the immediate postoperative X-ray, although lower than preoperative. The data obtained demonstrated the effectiveness of kyphoplasty in the treatment of vertebral collapse in MM. The results achieved with this minimally invasive technique were clinically and biomechanically satisfactory.
-
We report the clinical and radiological results on the safety and efficacy of an unusual surgical strategy coupling anterior cervical discectomy and fusion and total disc replacement in a single-stage procedure, in patients with symptomatic, multilevel cervical degenerative disc disease (DDD). The proposed hybrid, single-stage, fusion-nonfusion technique aims either at restoring or maintaining motion where appropriate or favouring bony fusion when indicated by degenerative changes. Twenty-four patients (mean age 46.7 years) with symptomatic, multilevel DDD, either soft disc hernia or different stage spondylosis per single level, with predominant anterior myeloradicular compression and absence of severe alterations of cervical spine sagittal alignment, have been operated using such hybrid technique. ⋯ None of the patients needed revision surgery for persisting or recurring symptoms, procedure-related complications or devices dislocations. To the authors' best knowledge, this is the first study with the longest available follow-up describing a different concept in the management of cervical multilevel DDD. Although larger series with longer follow-up are needed, in selected cases of symptomatic multilevel DDD, the proposed surgical strategy appears to be a safe and reliable application of combined arthroplasty and arthrodesis during a single surgical procedure.
-
Originally aimed at treating degenerative syndromes of the lumbar spine, percutaneous minimally invasive posterior fixation is nowadays even more frequently used to treat some thoracolumbar fractures. According to the modern principles of saving segment of motion, a short implant (one level above and one level below the injured vertebra) is generally used to stabilise the injured spine. Although the authors generally use a short percutaneous fixation in treating thoracolumbar fractures with good results, they observed some cases in which the high fragmentation of the vertebral body and the presence of other associated diseases (co-morbidities) did not recommend the use of a short construct. ⋯ At the 1-year follow-up, all patients except one, who died 11 months after the operation, did not show any radiologic signs of mobilisation or failure of the implant. Based on the results of the present series, the long percutaneous fixation seems to represent an effective and safe system to treat particular cases of vertebral lesions. In conclusion, the authors believe that a long implant might be an alternative surgical method compared to more aggressive or demanding procedures, which in a few patients could represent an overtreatment.
-
Total lumbar disc replacement (TDR) has been widely used as a treatment option for 2-level symptomatic degenerative disc disease. However, recent studies have presented conflicting results and some authors concluded that outcome deteriorated when disc replacement was performed bisegmentally, with an increase of complications for bisegmental replacements in comparison with monosegmental disc arthroplasty. The goal of the present retrospective study is to investigate results in a group of patients who have received bisegmental TDR with SB Charitè III artificial disc for degenerative disc disease with a minimum follow-up of 3 years, and to compare the results of 2-level disc replacement versus 1-level patients treated with the same prosthesis. ⋯ In the 1-level cases there were 2 minor complications (12.5%) and 2 major complications (12.5%) and a new revision surgery was required in 1 patient (6.25%). In conclusion, the use of 2-level disc replacement at last follow-up presented a higher incidence of complications than in cases with 1-level replacement. At the same time it was impossible to delineate a clear difference in evaluating the questionnaires between the follow-up results of patients receiving 2- and 1-level TDR: the 2-level group presented slightly lower scores at follow-up, but none was statistically significant.