Randomized Controlled TrialPositive end-expiratory pressure titration with electrical impedance tomography and pressure-volume curve: a randomized trial in moderate to severe ARDS.
The aim of the study was to compare titration of positive end-expiratory pressure (PEEP) with electrical impedance tomography (EIT) and with ventilator-embedded pressure-volume (PV) loop in moderate to severe acute respiratory distress syndrome (ARDS). ⋯ In moderate to severe ARDS, PEEP titration guided with EIT, compared with PV curve, might be associated with improved driving pressure and survival rate.
-
Physiological measurement · Apr 2009
Randomized Controlled TrialPoincaré analysis of an overnight arterial oxygen saturation signal applied to the diagnosis of sleep apnea hypopnea syndrome.
The analysis of oxygen desaturations is a basic variable in polysomnographic studies for the diagnosis of sleep apnea. Several algorithms operating in the time domain already exist for sleep apnea detection via pulse oximetry, but in a disadvantageous way--they achieve either a high sensitivity or a high specificity. The aim of this study was to assess whether an alternative analysis of arterial oxygen saturation (SaO2) signals from overnight pulse oximetry could yield essential information on the diagnosis of sleep apnea hypopnea syndrome (SAHS). ⋯ Results showed that the presence of apnea events in SAHS patients caused an increase in the SD1 Poincaré parameter. This conclusion was assessed prospectively using the test dataset. 90.9% sensitivity and 84.0% specificity were obtained in the test group. We conclude that Poincaré analysis could be useful in the study of SAHS, contributing to reduce the demand for polysomnographic studies in SAHS screening.
-
Physiological measurement · Aug 2005
Randomized Controlled Trial Comparative Study Clinical TrialVariability in time delay between two models of pulse oximeters for deriving the photoplethysmographic signals.
Pulse oximetry is commonly used as an arterial blood oxygen saturation (SaO2) measure. However, its other serial output, the photoplethysmography (PPG) signal, is not as well studied. Raw PPG signals can be used to estimate cardiovascular measures like pulse transit time (PTT) and possibly heart rate (HR). ⋯ Novametrix differed from ECG by 0.71+/-0.58% (p<0.05) while Masimo differed by 4.51+/-3.66% (p>0.05). Modern oximeters can be attractive for their improved SaO2 measurement. However, using raw PPG signals obtained directly from these oximeters for timing-related measurements warrants further investigations.