Anaesthesia
-
Randomized Controlled Trial Comparative Study
Tracheal intubation using the ILMA, C-Trach or McCoy laryngoscope in patients with simulated cervical spine injury.
A study of 90 patients was undertaken to compare intubation success rates of using either ILMA, C-Trach or McCoy laryngoscope in patients with simulated cervical spine injury. Insertion and intubation success rates, time taken to achieve intubation, airway complications and haemodynamic parameters were recorded. ⋯ Total intubation time was significantly longer in the ILMA (63 s, SD 36.5) group than in the C-Trach (41 s, SD 15.8) and McCoy (30 s, SD 7.4) groups (p < 0.05, p < 0.05, respectively). There were no significant differences in haemodynamic parameters among the groups at any time.
-
Randomized Controlled Trial Comparative Study
Paraesthesia during the needle-through-needle and the double segment technique for combined spinal epidural anaesthesia.
Paraesthesia during regional anaesthesia is an unpleasant sensation for patients and, more importantly, in some cases it is related to neurological injury. Relatively few studies have been conducted on the frequency of paraesthesia during combined spinal epidural anaesthesia. We compared two combined spinal epidural anaesthesia techniques: the needle-through-needle technique and the double segment technique in this respect. ⋯ Both techniques were performed using a 27G pencil point needle, an 18G Tuohy needle, and a 20G multiport epidural catheter from the same manufacturer. The overall frequency of paraesthesia was higher in the needle-through-needle technique group (56.9% vs. 31.6%, p = 0.011). The frequency of paraesthesia at spinal needle insertion was 20.7% in the needle-through-needle technique group and 8.8% in the double segment technique group; whereas the frequency of paraesthesia at epidural catheter insertion was 46.6% in the needle-through-needle technique group and 24.6% in the double segment technique group.
-
Comparative Study
Comparison of the Berman Intubating Airway and the Williams Airway Intubator for fibreoptic orotracheal intubation in anaesthetised patients.
Sixty patients with no clinical indicators of a difficult airway were selected to undergo a fibreoptic assessment after induction of general anaesthesia using both the Berman Intubating Airway and the Williams Airway Intubator. The bronchoscopic view and ease of railroading a tracheal tube during fibreoptic orotracheal intubation were studied. ⋯ The estimated odds ratio of obtaining an obstructed path was 3.06 times higher for the Berman than the Williams Airway. However, if the glottis could be reached with the bronchoscope, there was no significant difference in the degree of ease of intubation between the two airways.