Anaesthesia
-
Our aim was to compare peri-operative core temperatures and the incidence of hypothermia in obese and non-obese women with active forced-air warming. Twenty female patients scheduled for abdominal surgery were allocated to two groups according to body mass index. Ten obese (30.0-34.9 kg.m(-2) ) and 10 non-obese (18.5-24.9 kg.m(-2) ) women received forced-air warming on their lower limbs. ⋯ The incidences of intra-operative hypothermia were lower in the obese group (10%) compared with non-obese group (60%; p = 0.019). In the postoperative recovery phase, the mean (SD) core temperature data were higher in the obese group than in the non-obese group (36.2 (0.4) vs 35.6 (0.5) °C, respectively (p < 0.001)). In conclusion, obese female patients have higher peri-operative core temperature and a lower incidence of hypothermia compared with non-obese female patients during abdominal surgery with active forced-air warming.
-
Blood pressure measurement is an essential physiological measurement for all critically ill patients. Previous work has shown that non-invasive blood pressure is not an accurate reflection of invasive blood pressure measurement. In a transport environment, the effects of motion and vibration may make non-invasive blood pressure less accurate. ⋯ Thus, our data show that non-invasive blood pressure is not a precise reflection of invasive intra-arterial blood pressure. Mean blood pressure measured non-invasively may be a better marker of invasive blood pressure than systolic blood pressure. Our data show no evidence of non-invasive blood pressures being less accurate in an aeromedical transport environment.
-
Hypotension occurs in most caesarean sections under spinal anaesthesia, necessitating vasopressor administration. However, the optimal dosing regimen remains unclear. We have developed a novel vasopressor delivery system that automatically administers phenylephrine or ephedrine based on continuous non-invasive blood pressure monitoring. ⋯ The system maintained systolic blood pressure at a mean (SD) of -9.1 (7.0)% below baseline, with 5.4 (2.5)% fluctuation. Two patients (4%) experienced pre-delivery nausea. All 5-min Apgar scores were 9.
-
We investigated block heights that anaesthetists considered adequate for caesarean section to proceed under spinal anaesthesia. During 3 months, 15 obstetric anaesthetists recorded block height to touch, pinprick or cold when spinal anaesthesia was considered satisfactory for caesarean section to proceed. Median (IQR [range]) block height for touch, pinprick, first cold and icy were: T10 (T7-T12 [T3-L1]); T5 (T4-T6 [C7-L1]); T5 (T4-T6 [C7-L1]); and T3 (T2-T4 [C7-L1]), respectively. ⋯ Pairwise comparisons showed differences between all modalities (p < 0.001) apart from pinprick and first cold (p = 0.94). All women had satisfactory anaesthesia despite 76 (81%) having a block to touch below T6. Single modality assessment of block height, particularly using touch, may erroneously indicate inadequate anaesthesia for caesarean section.