A comparison of the Nexfin® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery.
The newly introduced Nexfin(®) device allows analysis of the blood pressure trace produced by a non-invasive finger cuff. We compared the cardiac output derived from the Nexfin and PiCCO, using transcardiopulmonary thermodilution, during cardiac surgery. Forty patients with preserved left ventricular function undergoing elective coronary artery bypass graft surgery were studied after induction of general anaesthesia and until discharge to the intensive care unit. ⋯ Bland-Altman analysis demonstrated the mean bias of Nexfin to be -0.1 (95% limits of agreement -0.6 to +0.5, percentage error 23%) and -0.1 (-0.8 to +0.6, 26%) l.min(-1).m(-2), before and after cardiopulmonary bypass, respectively. After a passive leg-raise was performed, there was also good correlation between the two methods, both before (r(2) = 0.72, p < 0.001) and after (r(2) = 0.76, p < 0.001) cardiopulmonary bypass. We conclude that the Nexfin is a reliable method of measuring cardiac output during and after cardiac surgery.
-
A caudal epidural injection was performed on a middle-aged woman for pain in her right foot. Although the procedure was uncomplicated and a good epidurogram was obtained, the patient went on to develop an orthostatic headache with generalised weakness and syncopal episodes that were treated successfully by epidural blood patching. We describe the aetiology, presentation and treatment of spontaneous intracranial hypotension and review the similarities with our patient's clinical presentation. We hypothesise as to how our intervention may have resulted in a dural tear.
-
Peripheral pulse oximetry has become a core monitoring modality in most fields of medicine. Pulse oximeters are used ubiquitously in operating theatres, hospital wards, outpatient clinics and general practice surgeries. This study used a portable spectrometer (Lightman(®), The Electrode Co. ⋯ Eighty-nine sensors (10.5%) were found to have a functional error of their electrical circuitry that could cause inaccuracy of measurement. Of the remaining 758 sensors, 169 (22.3%) were found to have emission spectra different from the manufacturers' specification that would cause an inaccuracy in saturation estimation of > 4% in the range of 70-100% saturation. This study has demonstrated that a significant proportion of pulse oximeter sensors may be inaccurate.
-
I report the case of a 57-year-old patient admitted to the intensive care unit with severe community-acquired pneumonia, complicated by prolonged mechanical ventilation of the lungs and intractable cardiac failure. He underwent percutaneous coronary angioplasty of the right coronary artery, but this did not improve his clinical condition. ⋯ As open surgery was felt to be not feasible, the patient underwent percutaneous repair of his mitral valve using the MitraClip® device, and, after months of ventilatory support, was then weaned from the ventilator in a matter of days. While the procedure itself and the technology employed are still under evaluation, I conclude that the technique of percutaneous mitral valve repair may be considered for similar patients for whom open repair is contraindicated.