Anaesthesia
-
Bougies are susceptible to becoming contaminated before or during use. Chlorhexidine wipes may have a residual antibacterial effect, potentially minimising bacterial transmission after bougie use or storage. We evaluated the decontaminant and antibacterial effectiveness of 70% alcohol/2% chlorhexidine wipes in laboratory, clinical and accelerated ageing studies, and conducted a telephone survey of normal practice. ⋯ Following 150 cleaning episodes, there was no physical or functional damage to the bougies. Eight out of nine hospitals in the East of England Health Region use re-usable bougies. We recommend that following decontamination, bougies should be wiped with 70% alcohol/2% chlorhexidine wipes, to retain antimicrobial activity during handling.
-
The 4th National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society (NAP4) analysed reports of serious events arising from airway management during anaesthesia, intensive care and the emergency department. We conducted supplementary telephone interviews with 12 anaesthetists who had reported to NAP4, aiming to identify causal factors using a method based on the Human Factors Investigation Tool (HFIT). ⋯ Protective factors, such as teamwork and communication, were also revealed. The post-report HFIT interview method identified relevant human factors and this approach merits further testing as part of the investigation of anaesthetic incidents.
-
We compared direct laryngoscopy with a Macintosh blade vs indirect bronchoscopy with a Trachway® stylet, for endobronchial intubation with a left-sided double-lumen tube. We allocated participants scheduled for thoracic surgery and who had normal predicted laryngoscopy, 30 to each group. ⋯ The rates of hoarseness on the first postoperative day, categorised as none/mild/moderate/severe, were 10/12/7/1 and 22/6/2/0, respectively, p = 0.008, without differences on subsequent days. Left endobronchial intubation with a double-lumen tube is slower using direct laryngoscopy and causes more hoarseness than indirect bronchoscopy with a Trachway stylet.
-
We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. ⋯ The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience.