Anaesthesia
-
To date, postoperative quality of recovery lacks a universally accepted definition and assessment technique. Current quality of recovery assessment tools vary in their development, breadth of assessment, validation, use of continuous vs dichotomous outcomes and focus on individual vs group recovery. They have progressed from identifying pure restitution of physiological parameters to multidimensional assessments of postoperative function and patient-focused outcomes. ⋯ A literature search identified 11 unique recovery assessment tools. The Postoperative Quality of Recovery Scale assesses recovery in multiple domains, including physiological, nociceptive, emotive, activities of daily living, cognition and patient satisfaction. It addresses recovery over time and compares individual patient data with base line, thus describing resumption of capacities and is an acceptable method for identification of individual patient recovery.
-
Randomized Controlled Trial
The effects of intra-operative dexmedetomidine on postoperative pain, side-effects and recovery in colorectal surgery.
In this double-blind, randomised study, 100 patients undergoing open or conventional laparoscopic colorectal surgery received an intra-operative loading dose of dexmedetomidine 1 μg.kg(-1) followed by an infusion of 0.5 μg.kg(-1) .h(-1) , or a bolus and infusion of saline 0.9% of equivalent volume. Forty-six patients in the dexmedetomidine group and 50 in the saline group completed the study. ⋯ From the data obtained in this study, we calculated a number needed to treat for effective pain relief of 4. Intra-operative dexmedetomidine in colorectal surgery resulted in a reduction in resting pain scores, but there was no morphine-sparing effect or improvement in patients' recovery outcome measures.
-
The Anaconda™ system is used to deliver inhalational sedation in the intensive care unit in mainland Europe. The new Mirus™ system also uses a reflector like the Anaconda; however, it also identifies end-tidal concentrations from the gas flow, injects anaesthetics during early inspiration, controls anaesthetic concentrations automatically, and can be used with desflurane, which is not possible using the Anaconda. We tested the Mirus with desflurane in the laboratory. ⋯ Efficiency was > 80% and was also deemed to be acceptable, but only when delivering a low concentration of desflurane (≤ 1.8%). By modifying the reflector, we improved efficiency up to a concentration of 3.6%. The Mirus appears to be a promising new device for long-term sedation with desflurane on the intensive care unit, but efficiency must be improved before routine clinical use becomes affordable.
-
Review Meta Analysis Comparative Study
A systematic review and meta-analysis of the i-gel(®) vs laryngeal mask airway in children.
We systematically reviewed randomised controlled trials of the i-gel® vs different types of laryngeal mask airway in children. We included nine studies. There was no evidence for differences in: rate of insertion at first attempt; insertion time; ease of insertion; or gastric tube insertion. ⋯ The relative rate (95% CI) of a good fibreoptic view through the i-gel was 1.10 (1.01-1.19), p = 0.02. There were no significant differences in the rates of complications, except for blood on the airway, relative rate with the i-gel 0.46 (0.23-0.91), p = 0.02. We concluded that the clinical performance of the i-gel and LMA was similar, except for three outcomes that favoured the i-gel.