Anaesthesia
-
Randomized Controlled Trial Comparative Study
Analysis of transthoracic echocardiographic data in major vascular surgery from a prospective randomised trial comparing sevoflurane and fentanyl with propofol and remifentanil anaesthesia.
The aim of this study was to define pre-operative echocardiographic data and explore if postoperative indices of cardiac function after open abdominal aortic surgery were affected by the anaesthetic regimen. We hypothesised that volatile anaesthesia would improve indices of cardiac function compared with total intravenous anaesthesia. Transthoracic echocardiography was performed pre-operatively in 78 patients randomly assigned to volatile anaesthesia and 76 to total intravenous anaesthesia, and compared with postoperative data. ⋯ N-terminal prohormone of brain natriuretic peptide increased on the first postoperative day (p < 0.001) and remained elevated after 30 days (p < 0.001) in both groups. Although postoperative echocardiographic alterations were most likely to be related to increased preload due to a substantial iatrogenic surplus of fluid, a component of peri-operative myocardial ischaemia cannot be excluded. Our hypothesis that volatile anaesthesia improved indices of cardiac function compared with total intravenous anaesthesia could not be verified.
-
Since the adverse consequences of accidental peri-operative hypothermia have been recognised, there has been a rapid expansion in the development of new warming equipment designed to prevent it. This is a review of peri-operative warming devices and a critique of the evidence assessing their performance. ⋯ We also discuss the challenge of fluid warming, looking particularly at how devices' performance varies according to flow rate. Our ultimate aim is to provide a guide through the bewildering array of devices on the market so that clinicians can make informed and accurate choices for their particular hospital environment.
-
Randomized Controlled Trial
A pilot study of cerebral tissue oxygenation and postoperative cognitive dysfunction among patients undergoing coronary artery bypass grafting randomised to surgery with or without cardiopulmonary bypass.
Coronary artery bypass surgery, performed with or without cardiopulmonary bypass, is frequently followed by postoperative cognitive decline. Near-infrared spectroscopy is commonly used to assess cerebral tissue oxygenation, especially during cardiac surgery. Recent studies have suggested an association between cerebral desaturation and postoperative cognitive dysfunction. ⋯ Three months after surgery, 11 patients (39%) in the cardiopulmonary bypass group displayed cognitive dysfunction, compared with four (14%) in the non-cardiopulmonary bypass group (p = 0.03). The use of cardiopulmonary bypass was identified as an independent risk factor for the development of late cognitive dysfunction (OR 6.4 (95% CI 1.2-33.0) p = 0.027. In conclusion, although cerebral oxygen desaturation was rare in our population, postoperative cognitive decline was common in both groups, suggesting that factors other than hypoxic neuronal injury are responsible.
-
Randomized Controlled Trial
The effect of audible alarms on anaesthesiologists' response times to adverse events in a simulated anaesthesia environment: a randomised trial.
Alarms are ubiquitous in anaesthetic practice, but their net effect on anaesthesiologists' performance and patient safety is debated. In this study, 27 anaesthesiologists performed two simulation sessions in random order; one session was programmed to include an alarm condition, with a standard, frequent, clearly audible alarm sound. During these sessions, adverse events were simulated and anaesthesiologists' response times to these events were recorded. ⋯ Pooled response times to atrial fibrillation and desaturation were fast, with a median (range [IQR]) of 8 (4-14 [1-41]) s and 9 (6-16 [1-44]) s, respectively. Pooled response times to an ST segment elevation on the ECG and an obstructed intravenous line were significantly slower, with median (IQR[range]) times of 34 (21-76[4-300]) s and 227 (95-399 [2-600]) s, respectively (p < 0.001). This study shows that in a simulated anaesthesia environment, response times to adverse events are similar in the absence or presence of an audible alarm, and that response times to various critical events differ.