We report 13 cases of presumed rocuronium-induced anaphylaxis in which sugammadex was administered with the intention of reversing the immunological reaction. Of these 13 cases, eight (62%) were later confirmed to be type-1 hypersensitivity reactions to rocuronium, three (23%) were triggered by an antibiotic and two (15%) were non-immunologically mediated. ⋯ Of the three cases in which the treating anaesthetist thought that sugammadex had been beneficial, one was not caused by rocuronium, one had no improvement in blood pressure and one required 8.5 times as much adrenaline in boluses after, compared with the period before, sugammadex administration. These data suggest that sugammadex does not modify the clinical course of a suspected hypersensitivity reaction.
-
Randomized Controlled Trial
Effectiveness of chest compression feedback during cardiopulmonary resuscitation in lateral tilted and semirecumbent positions: a randomised controlled simulation study.
Feedback devices have been shown to improve the quality of chest compression during cardiopulmonary resuscitation for patients in the supine position, but no studies have reported the effects of feedback devices on chest compression when the chest is tilted. Basic life support-trained providers were randomly assigned to administer chest compressions to a manikin in the supine, 30° left lateral tilt and 30° semirecumbent positions, with or without the aid of a feedback device incorporated into a smartphone. Thirty-six participants were studied. ⋯ In the semirecumbent position, the proportion of compressions of correct depth was 21 (0-87 [0-100])% with and 1 (0-26 [0-100])% without feedback (p = 0.05). Female participants applied chest compressions at a more accurate rate using the feedback device in the lateral tilted position but were unable to increase the chest compression depth, whereas male participants were able to increase the force of chest compression using the feedback device in the lateral tilted and semirecumbent positions. We conclude that a feedback device improves the application of chest compressions during simulated cardiopulmonary resuscitation when the chest is tilted.
-
Comparative Study
A comparison of the ease of tracheal intubation using a McGrath MAC(®) laryngoscope and a standard Macintosh laryngoscope.
We compared the McGrath MAC(®) videolaryngoscope when used as both a direct and an indirect laryngoscope with a standard Macintosh laryngoscope in patients without predictors of a difficult tracheal intubation. We found higher median Intubation Difficulty Scores with the McGrath MAC as a direct laryngoscope, 1 (0-3 [0-5]) than when using it as an indirect videolaryngoscope, 0 (0-1 [0-5]) or when using the Macintosh laryngoscope, 0 (0-1 [0-5]), p = 0.04. This was mirrored in the subjective user reporting, scored out of 10, of difficulty for each method 3.0 (2.0-3.4 [0.5-80]); 2.0 (1.0-3.9 [0-70]) and 2.0 (1.0-3.3 [0-70]), respectively (p = 0.01). ⋯ There was no difference between the groups in time taken to intubate or incidence of complications. There was no statistical difference in the performances as measured between the McGrath MAC used as an indirect videolaryngoscope and the Macintosh laryngoscope. We cannot recommend that the McGrath videolaryngoscope be used as a direct laryngscopic device in place of the Macintosh.
-
During and after cardiac surgery with cardiopulmonary bypass, high concentrations of oxygen are routinely administered, with the intention of preventing cellular hypoxia. We systematically reviewed the literature addressing the effects of arterial hyperoxia. Extensive evidence from pre-clinical experiments and clinical studies in other patient groups suggests predominant harm, caused by oxidative stress, vasoconstriction, perfusion heterogeneity and myocardial injury. ⋯ Current evidence is insufficient to specify optimal oxygen targets. Nevertheless, the safety of supraphysiological oxygen suppletion is unproven. Randomised studies with a variety of oxygen targets and inclusion of high-risk patients are needed to identify optimal oxygen targets during and after cardiac surgery.