Anaesthesia
-
We report 13 cases of presumed rocuronium-induced anaphylaxis in which sugammadex was administered with the intention of reversing the immunological reaction. Of these 13 cases, eight (62%) were later confirmed to be type-1 hypersensitivity reactions to rocuronium, three (23%) were triggered by an antibiotic and two (15%) were non-immunologically mediated. ⋯ Of the three cases in which the treating anaesthetist thought that sugammadex had been beneficial, one was not caused by rocuronium, one had no improvement in blood pressure and one required 8.5 times as much adrenaline in boluses after, compared with the period before, sugammadex administration. These data suggest that sugammadex does not modify the clinical course of a suspected hypersensitivity reaction.
-
Controlled Clinical Trial
Accuracy of conventional digital palpation and ultrasound of the cricothyroid membrane in obese women in labour.
Success of cricothyroidotomy depends on accurate identification of anatomical neck landmarks. Anaesthetists palpated the cricothyroid membrane of 28 obese and 28 non-obese women in labour (cut-off BMI 30 kg.m(-2) ) and marked the entry point for device insertion with an ultraviolet invisible pen. Ultrasonography was used to mark the midpoint of the cricothyroid membrane and the distance between the two marks was measured. ⋯ Increased neck circumference in obese patients was significantly associated with inaccuracy in locating the cricothyroid membrane. Percutaneous identification of the cricothyroid membrane in obese women in labour was poor. Pre-procedural ultrasound may help improved the identification of neck landmarks for cricothyroidotomy.
-
Randomized Controlled Trial
Effectiveness of chest compression feedback during cardiopulmonary resuscitation in lateral tilted and semirecumbent positions: a randomised controlled simulation study.
Feedback devices have been shown to improve the quality of chest compression during cardiopulmonary resuscitation for patients in the supine position, but no studies have reported the effects of feedback devices on chest compression when the chest is tilted. Basic life support-trained providers were randomly assigned to administer chest compressions to a manikin in the supine, 30° left lateral tilt and 30° semirecumbent positions, with or without the aid of a feedback device incorporated into a smartphone. Thirty-six participants were studied. ⋯ In the semirecumbent position, the proportion of compressions of correct depth was 21 (0-87 [0-100])% with and 1 (0-26 [0-100])% without feedback (p = 0.05). Female participants applied chest compressions at a more accurate rate using the feedback device in the lateral tilted position but were unable to increase the chest compression depth, whereas male participants were able to increase the force of chest compression using the feedback device in the lateral tilted and semirecumbent positions. We conclude that a feedback device improves the application of chest compressions during simulated cardiopulmonary resuscitation when the chest is tilted.