Anaesthesia
-
Review Meta Analysis Comparative Study
Comparison of streamlined liner of the pharynx airway (SLIPA(™) ) and laryngeal mask airway: a systematic review and meta-analysis.
We performed a systematic review to compare the efficacy and safety of the streamlined liner of the pharynx airway and laryngeal mask airway used in adults during general anaesthesia. We included 14 studies with studies with 1273 patients in total. There was no evidence of a difference between the two devices in insertion success rate on the first attempt (13 studies, 1143 patients), insertion time (seven studies, 576 patients), ease of insertion (five studies, 466 patients), oropharyngeal leak pressure (eight studies, 771 patients) and the quality of the fibreoptic view of the larynx through the device (three studies, 281 patients). ⋯ Other adverse events were comparable. Subgroup analysis suggested that the insertion by novice users might be faster and more successful with the streamlined liner of the pharynx airway than the laryngeal mask airway; however, this was from only two studies and 186 patients. The method of size selection of the streamlined liner of the pharynx airway device might also affect the speed of insertion: choosing according to the width of the patient's thyroid cartilage, rather than height, may produce better results.
-
Randomized Controlled Trial Comparative Study
A randomised, single-blind technical study comparing the ultrasonic visibility of smooth-surfaced and textured needles in a soft embalmed cadaver model.
Visibility of the needle tip and shaft is important during ultrasound-guided regional anaesthesia in order to prevent nerve trauma. Tip and shaft visibility is reduced when needles are inserted in-plane at wide angles and out-of-plane at narrow angles to the ultrasound probe. Although textured needles are more reflective than smooth needles, we hypothesised that poor visibility of the tip and shaft still remained using the above angle-probe combinations. ⋯ The median (IQR [range]) proportions of visible needle tips were 83% (67-83 [50-100]%) for the textured Tuohy, 75% (67-83 [33-83]%) for the textured single-shot needle and 33% (33-46 [0-50]%) for the smooth-surfaced Tuohy (p = 0.0007). Median (IQR [range]) needle shaft visibility was rated as 4.0 (3.5-4.7 [3.0-4.9]) for the textured Tuohy, 4.0 (3.8-4.5 [2.7-4.9]) for the textured single-shot needle and 3.0 (2.4-3.3 [2.3-3.5]) for the smooth-surfaced Tuohy (p = 0.015). Nevertheless, visibility was reduced at wide angles in-plane and narrow angles out-of-plane both for needle tips (p = 0.004) and shafts (p = 0.005).
-
Randomized Controlled Trial
Effective local anaesthetic volumes for sciatic nerve blockade: a clinical evaluation of the ED99.
Previous results in volunteers have indicated the effective dose in 99% of subjects (ED99 ) of local anaesthetic volume to be 0.10 ml.mm(-2) of cross-sectional nerve area for sciatic nerve blockade. The objective of this prospective, randomised, double-blind study was to investigate the ED99 of local anaesthetic for ultrasound-guided sciatic nerve blockade in patients undergoing foot surgery, according to Dixon's up-and-down method and probit analysis. ⋯ Thereafter, the volume of local anaesthetic was increased by 0.02 ml.mm(-2). The ED99 volume of local anaesthetic for ultrasound-guided sciatic nerve blockade was calculated to be 0.15 ml.mm(-2) cross-sectional nerve area, which is higher than the previously evaluated ED99 volume in volunteers.
-
Randomized Controlled Trial
Haemoconcentration of residual cardiopulmonary bypass blood using Hemosep(®) : a randomised controlled trial.
Cardiac surgery and cardiopulmonary bypass are associated with haemodilution, activation of haemostasis and blood transfusion. We undertook a randomised controlled trial that included 53 patients in order to compare autotransfusion of residual cardiopulmonary bypass blood with residual blood concentrated using the novel Hemosep(®) device. There was no difference in patients' mean (SD) haemoglobin concentration after autotransfusion of unprocessed blood compared with Hemosep; 103.5 (10.2) g.l(-1) vs 106.2 (12.4) g.l(-1), respectively, p = 0.40. ⋯ This was despite Hemosep's reducing the weight of the blood from a mean (SD) of 778.7 (243.0) g to 607.3 (248.2) g, p < 0.001. The haemoglobin concentration in the processed blood increased from a mean (SD) of 87.0 (15.1) g.l(-1) to 103.7 (17.4) g.l(-1), p < 0.001. We conclude that Hemosep is capable of haemoconcentration when employed to process residual cardiopulmonary bypass blood, but that this is insufficient to increase patient haemoglobin.
-
Concise guidelines are presented for the preparation and conduct of anaesthesia and surgery in patients undergoing cemented hemiarthroplasty for hip fracture. The Working Party specifically considered recent publications highlighting complications occurring during the peri-operative period. The advice presented is based on previously published advice and clinical studies.