Anaesthesia
-
Applying human factors principles to the design of clinical emergency guidelines is important. The UK Civil Aviation Authority uses a Checklist Assessment Tool for evaluating the content and usability of emergency drills before introduction into service on aircraft. We hypothesised that this model could be used to develop a generic medical tool. ⋯ Internal consistency, as assessed by Cronbach's alpha, was 0.74, 0.96 and 0.72 for the tool's three constituent domains of physical characteristics, content and layout/format, respectively. Inter-rater reliability, as assessed by Cohen's kappa, ranged from 0.33 to 0.72. The adoption of our tool has the potential to improve the usability of medical emergency guidelines.
-
Randomized Controlled Trial Comparative Study
A randomised controlled comparison between stimulating and standard catheters for lumbar plexus block.
The aim of this randomised, prospective, blinded study was to evaluate if stimulating catheters can decrease the minimum effective anaesthetic volume in 50% of patients during lumbar plexus block using mepivacaine 1.5% compared with standard catheters. Fifty-eight patients of ASA physical status 1-3 were randomly allocated to receive a lumbar plexus block via a stimulating or standard catheter, with 29 in each group. ⋯ Complete lumbar plexus block was achieved with the initial dose of mepivacaine in 29 (100%) patients in the stimulating catheter group and 20 (69%) patients in the standard catheter group (p = 0.002). This study showed that use of a stimulating catheter halves the minimum effective anaesthetic volume50 of mepivacaine 1.5% while increasing the success rate in patients receiving continuous lumbar plexus block.
-
Observational Study
Reliability of manikin-based studies: an evaluation of manikin characteristics and their impact on measurements of ventilatory variables.
Findings from manikin-based studies on ventilation are commonly directly extrapolated to clinical practice. The aim of this study was to determine how the use of manikins affects measurements of ventilatory variables. We connected a lung simulator to a manikin, which was then ventilated at different inspiratory flows. ⋯ Significant peak pressure deviations from 0.7 (0.1) cmH2 O to 10.6 (0.3) cmH2 O were also recorded during non-invasive ventilation (p < 0.001). Evaluation of manikin resistance and airway dead space may be essential to limit study bias. We suggest a recalibration of the recorded data if comparisons are made between different tests performed at different inspiratory flows.
-
Editorial Review
Peri-operative cessation of smoking: time for anaesthetists to act.