Anaesthesia
-
Multicenter Study
Prediction of 30-day mortality after hip fracture surgery by the Nottingham Hip Fracture Score and the Surgical Outcome Risk Tool.
The care of the elderly with hip fractures and their outcomes might be improved with resources targeted by the accurate calculation of risks of mortality and morbidity. We used a multicentre national dataset to evaluate and recalibrate the Nottingham Hip Fracture Score and Surgical Outcome Risk Tool. ⋯ We recommend that studies test these scores for patients with hip fractures in other countries. We also recommend these models are compared with case-mix adjustment tools used in the UK.
-
Randomized Controlled Trial
The effectiveness of pulse oximetry sonification enhanced with tremolo and brightness for distinguishing clinically important oxygen saturation ranges: a laboratory study.
Our study examined the effectiveness of pulse oximetry sonification enhanced with acoustic tremolo and brightness to help listeners differentiate clinically relevant oxygen saturation ranges. In a series of trials lasting 30 s each, 76 undergraduate participants identified final oxygen saturation range ( ⋯ 100% to 97%; Low: 96% to 90%; Critical: 89% and below), and detected threshold transitions into and out of the target range using conventional sonification (n = 38) or enhanced sonification (n = 38). Median (IQR [range]) accuracy for range identification with the conventional sonification was 80 (70-85 [45-95])%, whereas with the enhanced sonification it was 100 (99-100 [80-100])%; p < 0.001. Accuracy for detecting threshold transitions with the conventional sonification was 60 (50-75 [30-95])%, but with the enhanced sonification it was 100 (95-100 [75-100]%; p < 0.001. Participants can identify clinically meaningful oxygen saturation ranges and detect threshold transitions more accurately with enhanced sonification than with conventional sonification.
-
Comparative Study
Comparison of seven videolaryngoscopes with the Macintosh laryngoscope in manikins by experienced and novice personnel.
Videolaryngoscopy is often reserved for 'anticipated' difficult airways, but thereby can result in a higher overall rate of complications. We observed 65 anaesthetists, 67 residents in anaesthesia, 56 paramedics and 65 medical students, intubating the trachea of a standardised manikin model with a normal airway using seven devices: Macintosh classic laryngoscope, Airtraq(®) , Storz C-MAC(®) , Coopdech VLP-100(®) , Storz C-MAC D-Blade(®) , GlideScope Cobalt(®) , McGrath Series5(®) and Pentax AWS(®) ) in random order. Time to and proportion of successful intubation, complications and user satisfaction were compared. ⋯ All groups needed significantly more attempts using the Airtraq and Pentax AWS (all p < 0.05). Devices with a Macintosh-type blade (classic laryngoscope and C-MAC) scored highest in user satisfaction. Our results underline the importance of variability in device performance across individuals and staff groups, which have important implications for which devices hospital providers should rationally purchase.
-
This study sought to identify changes in hepatic flood flow and cardiac output during prone positioning on surgical bolsters in awake volunteers, and was prompted by a local incident of significant hepatic dysfunction following surgery in the prone position. Cardiac output was determined using the non-invasive Peñáz technique, and plasma disappearance rate of indocyanine green (ICG-PDR) was measured as a surrogate maker for hepatic blood flow along with serum hepatic enzyme assays. Measurements were made after one hour in supine, prone and returned supine positions. ⋯ There were significant changes in the disappearance rate of indocyanine green, which decreased this from mean (SD) 31.1 (9.70) supine to 19.6 (4.37)%.min prone, respectively (p = 0.02), increasing on return to the supine position to 24.6 (5.54)%.min (p = 0.019). Cardiac output was also significantly reduced when changing from the supine to the prone position, from mean (SD) 4.7 (1.0 to 3.5 (1.1) (l.min(-1) ), respectively (p = 0.002). We demonstrated an acute and reversible change in both hepatocellular function and cardiac output associated with the prone position.