Anaesthesia
-
Emergency cricothyrotomy is a common feature in all difficult airway algorithms. It is the final step following a 'can't intubate, can't oxygenate' scenario. It is rarely performed and has a significant failure rate. ⋯ The cricothyroid membrane height in the study population was much smaller than that previously reported. Practitioners encountering patients who may require an emergency surgical airway should be aware of these data. Rescue airway equipment with variety of external diameters should be immediately available.
-
Randomized Controlled Trial
Intra-operative protective mechanical ventilation in lung transplantation: a randomised, controlled trial.
Primary graft dysfunction occurs in up to 25% of patients after lung transplantation. Contributing factors include ventilator-induced lung injury, cardiopulmonary bypass, ischaemia-reperfusion injury and excessive fluid administration. We evaluated the feasibility, safety and efficacy of an open-lung protective ventilation strategy aimed at reducing ventilator-induced lung injury. ⋯ The primary outcome was not different between groups (mean (SD) PaO2 /FI O2 ratio control group 340 (111) vs. alveolar recruitment group 404 (153); adjusted p = 0.26). Patients in the control group had poorer mean (SD) PaO2 /FI O2 ratios at the end of the surgical procedure and a longer median (IQR [range]) time to tracheal extubation compared with the alveolar recruitment group (308 (144) vs. 402 (154) (p = 0.03) and 18 (10-27 [5-468]) h vs. 15 (11-36 [5-115]) h (p = 0.01), respectively). An open-lung protective ventilation strategy during surgery for lung transplantation is feasible, safe and achieves favourable ventilation parameters.
-
Randomized Controlled Trial
A randomised, controlled trial evaluating a low cost, 3D-printed bronchoscopy simulator.
Low-fidelity, simulation-based psychomotor skills training is a valuable first step in the educational approach to mastering complex procedural skills. We developed a cost-effective bronchial tree simulator based on a human thorax computed tomography scan using rapid-prototyping (3D-print) technology. This randomised, single-blind study evaluated how realistic our 3D-printed simulator would mimic human anatomy compared with commercially available bronchial tree simulators (Laerdal® Airway Management Trainer with Bronchial Tree and AirSim Advance Bronchi, Stavanger, Norway). ⋯ The 3D-printed simulator was rated most realistic for the localisation of the right upper lobe bronchial lumen (p = 0.002), but no differences were found in placement of a bronchial blocker or for aspiration of fluid (p = 0.792 and p = 0.057) compared with using the commercially available simulators. Overall, the 3D-printed simulator was rated most realistic (p = 0.021). Given the substantially lower costs for the 3D-printed simulator (£85 (€100/US$110) compared with > ~ £2000 (€2350/US$2590) for the commercially available simulators), our 3D-printed simulator provides an inexpensive alternative for learning bronchoscopy skills, and offers the possibility of practising procedures on patient-specific models before attempting them in clinical practice.
-
The clinical effectiveness of patient-controlled analgesia has been demonstrated in a variety of settings. However, patient-controlled analgesia is rarely utilised in the Emergency Department. The aim of this study was to compare the cost-effectiveness of patient-controlled analgesia vs. standard care in participants admitted to hospital from the Emergency Department with pain due to traumatic injury or non-traumatic abdominal pain. ⋯ Sampling variation was estimated using bootstrap methods and the effects of parameter uncertainty explored in a sensitivity analysis. The cost per hour in moderate or severe pain averted was estimated as £24.77 (€29.05, US$30.80) (bootstrap estimated 95%CI £8.72 to £89.17) for participants suffering pain from traumatic injuries and £15.17 (€17.79, US$18.86) (bootstrap estimate 95%CI £9.03 to £46.00) for participants with non-traumatic abdominal pain. Overall costs were higher with patient-controlled analgesia than standard care in both groups: pain from traumatic injuries incurred an additional £18.58 (€21.79 US$23.10) (95%CI £15.81 to £21.35) per 12 h; and non-traumatic abdominal pain an additional £20.18 (€23.67 US$25.09) (95%CI £19.45 to £20.84) per 12 h.