Anaesthesia
-
The association between intra-operative hypotension and postoperative acute kidney injury, mortality and length of stay has not been comprehensively evaluated in a large single-centre hip fracture population. We analysed electronic anaesthesia records of 1063 patients undergoing unilateral hip fracture surgery, collected from 2015 to 2018. Acute kidney injury, 3-, 30- and 365-day mortality and length of stay were evaluated to assess the relationship between intra-operative hypotension absolute values (≤ 55, 60, 65, 70 and 75 mmHg) and duration of hypotension. ⋯ Three-day mortality was associated with delay to surgery ? 48 hours, whilst 30-day and 365-day mortality was associated with delay to surgery ≥ 48 hours, impaired cognition and cardiac/renal comorbidities. While the rate of acute kidney injury was similar to other studies, use of vasopressors and fluids to reduce the time spent at hypotensive levels failed to reduce this complication. Intra-operative hypotension at the levels observed in this cohort may not be an important determinant of acute kidney injury, postoperative mortality and length of stay.
-
Observational Study
The effect of patient ethnicity on the accuracy of peripheral pulse oximetry in patients with COVID-19 pneumonitis: a single-centre, retrospective analysis.
Pulse oximetry is used widely to titrate oxygen therapy and for triage in patients who are critically ill. However, there are concerns regarding the accuracy of pulse oximetry in patients with COVID-19 pneumonitis and in patients who have a greater degree of skin pigmentation. We aimed to determine the impact of patient ethnicity on the accuracy of peripheral pulse oximetry in patients who were critically ill with COVID-19 pneumonitis by conducting a retrospective observational study comparing paired measurements of arterial oxygen saturation measured by co-oximetry on arterial blood gas analysis (SaO2 ) and the corresponding peripheral oxygenation saturation measured by pulse oximetry (Sp O2 ). ⋯ Bias (limits of agreement) between SaO2 and Sp O2 measurements was 0.05% (-2.21-2.30). Patient ethnicity did not alter this to a clinically significant degree: 0.28% (1.79-2.35), -0.33% (-2.47-2.35) and -0.75% (-3.47-1.97) for patients of White, Asian and Black ethnic origin, respectively. In patients with COVID-19 pneumonitis, Sp O2 measurements showed a level of agreement with SaO2 values that was in line with previous work, and this was not affected by patient ethnicity.